Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

402
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
402
Structural Joints: Synovial Joints01:16

Structural Joints: Synovial Joints

7.2K
Synovial joints are the most common type of joint in the body. A key structural characteristic for a synovial joint is the presence of a joint cavity. This fluid-filled space is where the articulating surfaces of the bones contact each other. Also, unlike fibrous or cartilaginous joints, the articulating bone surfaces at a synovial joint are not directly connected to each other with fibrous connective tissue or cartilage. This gives the bones of a synovial joint the ability to move smoothly...
7.2K
Structural Joints: Fibrous Joints01:03

Structural Joints: Fibrous Joints

3.9K
Fibrous joints are a type of joint where the bones are connected by fibrous connective tissue. These joints provide stability and minimal to no movement between the articulating bones. There are three types of fibrous joints.
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
3.9K
Structural Joints: Cartilaginous Joints01:17

Structural Joints: Cartilaginous Joints

4.2K
As the name indicates, at a cartilaginous joint, the adjacent bones are united by cartilage, a tough but flexible type of connective tissue. Unlike synovial joints, these types of joints lack a joint cavity and involve bones joined together by either hyaline cartilage or fibrocartilage.
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary...
4.2K
Joints01:26

Joints

35.8K
Joints, also called articulations or articular surfaces, are points at which ligaments or other tissues connect adjacent bones. Joints permit movement and stability, and can be classified based on their structure or function.
Structural joint classifications are based on the material that makes up the joint as well as whether or not the joint contains a space between the bones. Joints are structurally classified as fibrous, cartilaginous, or synovial.
Fibrous Joints Are Immovable
The bones of a...
35.8K
Method of Joints01:30

Method of Joints

1.3K
The method of joints is a commonly used technique to analyze the forces in structural trusses. The method is based on the principle of equilibrium, which assumes that the truss members are connected by frictionless pins. The forces at each joint can be determined by considering the equilibrium of the forces acting on that joint.
Since plane truss members are in the same plane, each joint is subjected to a coplanar and concurrent force system. To apply the method of joints, the first step is to...
1.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effect of Medicaid coverage of tobacco-dependence treatments on smoking cessation.

International journal of environmental research and public health·2010
Same author

Cytokine and autoantibody patterns in acute liver failure.

Journal of immunotoxicology·2009
Same author

A novel scoring system for prognostic prediction in d-galactosamine/lipopolysaccharide-induced fulminant hepatic failure BALB/c mice.

BMC gastroenterology·2009
Same author

Mammalian target of rapamycin signaling pathway contributes to glioma progression and patients' prognosis.

The Journal of surgical research·2009
Same author

Estrogen receptor neurobiology and its potential for translation into broad spectrum therapeutics for CNS disorders.

Current molecular pharmacology·2009
Same author

Transcriptional and post-translational regulation of adiponectin.

The Biochemical journal·2009

Related Experiment Video

Updated: Feb 11, 2026

Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
08:29

Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)

Published on: January 7, 2019

11.9K

A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements.

Feng Liu1, Li Feng1, Junyuan Wang1

  • 1School of Mechanical Engineering, North University of China, PR China.

Journal of the Mechanical Behavior of Biomedical Materials
|April 29, 2018
PubMed
Summary

Edge loading in hip replacements can be avoided by controlling the translational mismatch between the cup and head centers. Maintaining a 45° cup inclination is crucial for reducing edge loading and implant wear.

Keywords:
Ceramic-on-ceramic bearingsEdge loadingHip joint alignmentHip joint replacementMulti-body dynamicsWear

More Related Videos

Additive Manufacturing of Functionally Graded Ceramic Materials by Stereolithography
06:53

Additive Manufacturing of Functionally Graded Ceramic Materials by Stereolithography

Published on: January 25, 2019

15.1K
Fused Filament Fabrication FFF of Metal-Ceramic Components
08:43

Fused Filament Fabrication FFF of Metal-Ceramic Components

Published on: January 11, 2019

18.1K

Related Experiment Videos

Last Updated: Feb 11, 2026

Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
08:29

Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)

Published on: January 7, 2019

11.9K
Additive Manufacturing of Functionally Graded Ceramic Materials by Stereolithography
06:53

Additive Manufacturing of Functionally Graded Ceramic Materials by Stereolithography

Published on: January 25, 2019

15.1K
Fused Filament Fabrication FFF of Metal-Ceramic Components
08:43

Fused Filament Fabrication FFF of Metal-Ceramic Components

Published on: January 11, 2019

18.1K

Area of Science:

  • Biomedical Engineering
  • Orthopedic Surgery
  • Materials Science

Background:

  • Edge loading in ceramic-on-ceramic hip replacements causes severe wear and early implant failure.
  • This adverse condition results from direct contact between the femoral head and the acetabular cup rim.
  • It is linked to translational mismatch in the centers of rotation and dynamic separation during gait.

Purpose of the Study:

  • To refine a computational model for predicting edge loading in hip implants.
  • To enhance understanding of the mechanisms causing edge loading.
  • To provide design and surgical guidance for mitigating edge loading and wear.

Main Methods:

  • Development and application of a dynamic contact model using multi-body dynamics simulation (MSC ADAMS).
  • Computational analysis to calculate contact forces and characterize edge loading.
  • Investigation of the influence of translational mismatch and cup inclination on edge loading.

Main Results:

  • Edge loading can be prevented with a translational mismatch of approximately 1.0 mm for a 45° cup inclination.
  • Correct cup inclination (45°) is vital for minimizing edge loading severity.
  • Increased swing phase load can help avoid edge loading within specific ranges of translational mismatch.

Conclusions:

  • Computational modeling is effective for studying edge loading in hip replacements.
  • Precise control of component positioning, particularly cup inclination, is critical for preventing edge loading.
  • Findings offer guidance for designing less prone implants and improving surgical techniques to reduce wear and failure.