Prognostic Impact of Calcium Score after Transcatheter Aortic Valve Implantation Performed With New Generation
Mariama Akodad1, Benoit Lattuca2, Audrey Agullo1
1Department of Cardiology, University Hospital of Montpellier, France.
Abstract:
Calcium score (CS) is a well-known prognostic factor after transcatheter aortic valve implantation (TAVI) performed with first generation prosthesis but few data are available concerning new generation valves. The aim of this study was to evaluate if CS remains a prognostic factor after Sapien 3 and Evolut R valves implantation. Agatston CS was evaluated on multislice computed tomography before TAVI in 346 patients implanted with Sapien XT (n = 61), CoreValve (n = 57) devices, (group 1, n = 118), and with new generation Sapien 3 (n = 147), Evolut R (n = 81) prosthesis, (group 2, n = 228). Major adverse cardiovascular events and aortic regurgitation (AR) were evaluated at 1 month. The 2 groups were similar at baseline except for logistic Euroscore (20.1% in group 1 vs 15.0 % in group 2; p = 0.001), chronic renal failure (44.1% vs 37.2% respectively, p = 0.007) and preprocedural CS (4,092 ± 2,176 vs 3,682 ± 2,109 respectively, p = 0.022). In group 1, 28 patients (23.7%) had adverse clinical events vs 21 (9.2%) in group 2 (p <0.01). In multivariate analysis, a higher CS was predictive of adverse events in group 1 (5,785 ± 3,285 vs 3,565 ± 1,331 p <0.0001) but not in group 2 (p = 0.28). A higher CS was associated with AR in group 1 (6,234 ± 2711 vs 3,429 ± 1,505; p <0.001) and in patients implanted with an Evolut R device from group 2 (4,085 ± 3,645 vs 2,551 ± 1,356; p = 0.01). In conclusion, CS appears as an important prognostic factor of major events after TAVI with first generation valves but not with new generation devices. CS remains associated with AR only with new generation self-expandable Evolut R devices.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Introduction to z Scores
z scores...
Introduction to z Scores
z scores...
z Scores and Area Under the Curve
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Impact of Groups on Groups