Bacterial Reduction after Gutta-Percha Removal with Single vs. Multiple Instrument Systems

Felipe Xavier1, Giselle Nevares1, Luciana Gominho2

  • 1Department of Operative Dentistry and Endodontics, Dental College of Pernambuco, University of Pernambuco, Pernambuco, Brazil.

Summary

Combined rotating instruments were more effective than single reciprocating instruments in reducing Enterococcus faecalis after gutta-percha removal. Neither system fully eliminated root canal infection, suggesting additional methods are needed.

Related Concept Videos

Multiple Pipe Systems01:21

Multiple Pipe Systems

Multipipe systems consist of complex configurations of interconnected pipes designed to transport fluids efficiently across intricate networks. They are essential in engineering applications requiring precise control over flow distribution, pressure, and head loss. They are categorized into series, parallel, loop, and network configurations, each distinguished by unique flow characteristics and applications.
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
1.2K
Single Pipe Systems01:24

Single Pipe Systems

In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
462
Gram-negative Bacterial Protein Secretion Systems01:17

Gram-negative Bacterial Protein Secretion Systems

Gram-negative bacteria utilize sophisticated protein secretion systems to transport proteins across their double-membrane envelope into the extracellular environment or host cells. Based on their mechanism of action, these systems are classified into one-step and two-step pathways.One-Step Secretion Systems (Types I, III, IV, and VI)One-step secretion systems bypass the periplasm entirely, forming a continuous channel that spans both the inner and outer membranes:Type I Secretion System (T1SS):...
1.0K
Oxidation-Reduction Reactions03:11

Oxidation-Reduction Reactions

Oxidation–Reduction Reactions
75.8K
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
782
Instrumentation Amplifier01:25

Instrumentation Amplifier

An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.1K