Related Experiment Video
Updated: Feb 11, 2026

Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Cerebral protection devices in transcatheter aortic valve replacement: a clinical meta-analysis of randomized
1The Collaborative Research (CORE) Group, Macquarie University, Sydney, Australia.
Background:
Neurological complications after undergoing transcatheter aortic valve replacement (TAVR) may be reduced with cerebral protection (CP) devices. However, randomized controlled trials (RCTs) have failed to demonstrate convincing evidence of improvements in hard clinical endpoints in patients with CP. The aim of this study was to compare clinical outcomes of TAVR patients with and without CP devices.
Methods:
Electronic searches were performed using four electronic databases from their dates of inception to May 2017. RCTs that reported outcomes for patient cohorts that underwent TAVR procedures with and without CP were included. Crude odds ratios (ORs) and 95% confidence intervals were calculated using random effects model.
Results:
A total of five RCTs were included, totalling 643 patients, 386 of whom were randomized to TAVR + CP and 257 with TAVR only. The primary composite endpoint of all-cause mortality and stroke at 30 days was lower in patients undergoing CP devices compared to those patients with TAVR alone (OR, 0.54; 95% CI, 0.30 to 0.98). Use of CP devices was also associated with lower new total lesion volume (standardised mean difference, -0.49; 95% CI, -0.96 to -0.03). There was a non-significant reduction in the risk of secondary clinical endpoints of all-cause mortality, stroke, life-threatening bleed, acute kidney injury and major vascular complications in patients randomized to TAVR + CP.
Conclusions:
Use of CP devices in TAVR appears to be safe and may be associated with a reduction in stroke/death.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
07:46Author Spotlight: Revolutionizing Remote Surgery with Augmented Reality and Robotics for Enhanced Precision and Accessibility
Published on: August 9, 2024
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Trial and Error and Algorithm
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...