Optimising lameness detection in dairy cattle by using handheld infrared thermometers
Related Experiment Video
Updated: Feb 11, 2026

Measuring Liver Mitochondrial Oxygen Consumption and Proton Leak Kinetics to Estimate Mitochondrial Respiration in Holstein Dairy Cattle
Published on: November 30, 2018
Yi-Chun Lin1,2, Siobhan Mullan2, David C J Main2
1School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan.
Abstract:
Lameness is one of the most serious economic and welfare issues in the dairy industry. Early detection of lameness can be difficult, but provision of early treatment is crucial. Previous studies have used infrared thermography to show that increased foot temperature (FT) is associated with lameness and foot lesions. However, poor accuracy has limited the management application potential. This study analysed ambient-temperature (AT)-adjusted foot-surface temperatures and temperature differences between the hind feet of individual cows to enhance lameness detection. Cow FTs were recorded on a 990-cow farm using an infrared thermometer fortnightly for 6 months. Additionally, mobility level was scored using the AHDB Dairy 4-point scale. The averages of FTs and ATs were 23.83 ± 0.03°C and 13.99 ± 1.60°C, respectively. The FT of cows with lameness was significantly higher than that of cows without lameness (P < 0.001). Increases in FTs correlated with the mobility score (MS) (P < 0.001). According to receiver operating characteristic (ROC) curves, the optimal threshold based on actual FTs was 23.3°C with 78.5% sensitivity and 39.2% specificity. However, the ROC curve for the AT-adjusted FT and FT difference parameters showed minimal improvements over the FT in detecting lameness. In conclusion, the infrared thermometer results demonstrated the association between elevated FTs and lameness, but further improvements to this detection technique will be required before it can be implemented as a management tool for detecting cows that could benefit from treatment. With additional validation, the technique could be used as a screening device to identify cows in need of further assessment.
Related Concept Videos
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...
Gas Thermometers and the Kelvin Scale
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...