Bioanalytical method development and validation of HPLCUV assay for the quantification of SHetA2 in mouse and human
Ankur Sharma1, Elangovan Thavathiru2, Doris Mangiaracina Benbrook1,2
1Department of Pharmaceutical Sciences, College of Pharmacy, University of Oklahoma Health Sciences Center, 1110 N. Stonewall Ave. CPB331, Oklahoma City, Oklahoma 73117-1200, USA.
Background:
SHetA2 is an oral anticancer agent being investigated for cancer treatment and prevention. The aim of this study was to develop and validate a simple, cost-effective, and sensitive HPLC-UV method for the quantification of SHetA2 in biological samples and to apply the method to pharmacokinetic studies of the drug.
Methods:
Sample preparation for mouse and human plasmas involved liquid-liquid precipitation and extraction using chilled acetonitrile with 2, 3-Diphenylquinoxaline as an internal standard. The separation of SHetA2 and internal standard was achieved via Waters XBridge™ BEH 130 C18 (3.5 μm, 2.1×150 mm) column coupled with a Waters XBridge™ C-18 (3.5 μm, 2.1×10 mm) guard column using 65% v/v acetonitrile: distilled water as a mobile phase in an isocratic mode with a flow rate of 0.18 ml/min. The analytes were eluted at a detection wavelength of 341 nm at a column temperature of 25°C.
Results:
The method was validated across a range of 5-1000 ng/ml for SHetA2 in plasma, with a lower limit of quantification of 5 ng/ml. The method showed high recovery in human (79.9-81.8%) and mouse (95.4-109.2%) plasma with no matrix effect. The intra- and inter-day accuracy and precision studies demonstrated that the method was specific, sensitive, and reliable. Stability studies showed that SHetA2 is stable for 20 h postoperatively in the auto sampler, and for six weeks at -80°C in plasma. Repetitive freezing and thawing may be avoided by preparing the aliquots and storing them at -80°C. The developed method was successfully applied to study the plasma pharmacokinetics of SHetA2 in tumor-bearing nude mice after intravenous and oral administration.
Conclusion:
A novel method for quantifying SHetA2 in mouse and human plasmas has been validated and is being applied for pharmacokinetic evaluation of SHetA2 in tumor-bearing mice. The developed method will be utilized for the quantification of SHetA2 in clinical studies.
More Related Videos
08:26Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
Published on: June 14, 2018
07:23Author Spotlight: Developing a Simple and Robust Hepatic Model for Pharmacological and Toxicological Applications
Published on: October 20, 2023
Related Concept Videos
Measurement of Bioavailability: Pharmacokinetic Methods
Reliability and Validity
In Vitro Drug Release Testing: Overview, Development and Validation
Development of Analytical Methods
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...