Background:
The assessment of clinical guideline adherence for the evaluation of pulmonary embolism (PE) via computed tomography pulmonary angiography (CTPA) currently requires either labor-intensive, retrospective chart review or prospective collection of PE risk scores at the time of CTPA order. The recording of clinical data in a structured manner in the electronic health record (EHR) may make it possible to automate the calculation of a patient's PE risk classification and determine whether the CTPA order was guideline concordant.
Objectives:
The objective of this study was to measure the performance of automated, structured data-only versions of the Wells and revised Geneva risk scores in emergency department (ED) encounters during which a CTPA was ordered. The hypothesis was that such an automated method would classify a patient's PE risk with high accuracy compared to manual chart review.
Methods:
We developed automated, structured data-only versions of the Wells and revised Geneva risk scores to classify 212 ED encounters during which a CTPA was performed as "PE likely" or "PE unlikely." We then combined these classifications with D-dimer ordering data to assess each encounter as guideline concordant or discordant. The accuracy of these automated classifications and assessments of guideline concordance were determined by comparing them to classifications and concordance based on the complete Wells and revised Geneva scores derived via abstractor manual chart review.
Results:
The automatically derived Wells and revised Geneva risk classifications were 91.5 and 92% accurate compared to the manually determined classifications, respectively. There was no statistically significant difference between guideline adherence calculated by the automated scores compared to manual chart review (Wells, 70.8% vs. 75%, p = 0.33; revised Geneva, 65.6% vs. 66%, p = 0.92).
Conclusion:
The Wells and revised Geneva score risk classifications can be approximated with high accuracy using automated extraction of structured EHR data elements in patients who received a CTPA. Combining these automated scores with D-dimer ordering data allows for the automated assessment of clinical guideline adherence for CTPA ordering in the ED, without the burden of manual chart review.
Related Concept Videos
Pulmonary Embolism I: Introduction
Pulmonary Embolism III: Nursing Management
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...