Related Experiment Video
Updated: Feb 11, 2026

08:43
Calibration Procedures for Orthogonal Superposition Rheology
Published on: November 18, 2020
2.4K
Orthogonal Photolysis of Protecting Groups
1Department of Organic Chemistry, University of Geneva 30 quai Ernest Ansermet, 1211 Geneva 4 (Switzerland) Fax: (+41) 22-328-7396.
Angewandte Chemie (International Ed. in English)
|May 2, 2018
Abstract:
The selective activation of photolabile protecting groups was made possible by the use of monochromatic light of suitable wavelength. This new approach allowed the orthogonal deprotection of a substrate containing several photosensitive groups.
More Related Videos
Related Concept Videos
Orthogonal Trajectories
71
Orthogonal trajectories describe the geometric relationship between two families of curves that intersect each other at right angles. One illustrative case involves a family of parabolas that open sideways along the x-axis. These curves share a common shape but differ by a scaling parameter, resulting in a set of curves that all pass through the origin and widen at different rates.Determining Orthogonal TrajectoriesTo identify the orthogonal trajectories for these parabolas, the first step...
71
Protection of Alcohols
8.1K
This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.1K
Zones of Protection
812
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
812
Protecting Self-Esteem
234
Self-esteem, a central component of psychological well-being, is actively maintained through various cognitive and behavioral strategies. Individuals employ specific mechanisms to preserve a positive self-concept and mitigate threats to their self-worth, particularly in contexts involving social evaluation or personal feedback. Four primary techniques are commonly used to sustain self-esteem.Manipulating AppraisalsOne prominent strategy involves manipulating appraisals from others. Individuals...
234
Radial System Protection
447
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
447
Line Protection with Impedance Relays
462
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
462

