Objective: Vaginal examination is widely used to assess the progress of labor; however, it is subjective and poorly reproducible. We aim to assess the feasibility and accuracy of transabdominal and transperineal ultrasound compared to vaginal examination in the assessment of labor and its progress. Methods: Women were recruited as they presented for assessment of labor to a tertiary inner city maternity service. Paired vaginal and ultrasound assessments were performed in 192 women at 24-42 weeks. Fetal head position was assessed by transabdominal ultrasound defined in relation to the occiput position transformed to a 12-hour clock face; fetal head station defined as head-perineum distance by transperineal ultrasound; cervical dilatation by anterior to posterior cervical rim measurement and caput succedaneum by skin-skull distance on transperineal ultrasound. Results: Fetal head position was recorded in 99.7% (298/299) of US and 51.5% (154/299) on vaginal examination (p < .0001 1 ). Bland-Altman analysis showed 95% limits of agreement, -5.31 to 4.84 clock hours. Head station was recorded in 96.3% (308/320) on vaginal examination (VE) and 95.9% (307/320) on US (p = .79 1 ). Head station and head perineum distance were negatively correlated (Spearman's r = -.57, p < .0001). 54.4% (178/327) of cervical dilatation measurements were determined using US and 100% on VE/speculum (p < .0001). Bland-Altman analysis showed 95% limits of agreement -2.51-2.16 cm. The presence of caput could be assessed in 98.4% (315/320) of US and was commented in 95.3% (305/320) of VEs, with agreement for the presence of caput of 76% (p < .05). Fetuses with caput greater than 10 mm had significantly lower head station (p < .0001). Conclusions: We describe comprehensive ultrasound assessments in the labor room that could be translated to the assessment of women in labor. Fetal head position is unreliably determined by vaginal examination and agrees poorly with US. Head perineum distance has a moderate correlation with fetal head station in relation to the ischial spines based on vaginal examination. Cervical dilatation is not reliably assessed by ultrasound except at dilatations of less than 4 cm. Caput is readily quantifiable by ultrasound and its presence is associated with lower fetal head station. Transabdominal and transperineal ultrasound is feasible in the labor room with an accuracy that is generally greater than vaginal examinations.

Related Concept Videos

Improving Translational Accuracy02:07

Improving Translational Accuracy

Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
15.0K
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.7K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
104.1K
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.6K
Accuracy and Precision01:52

Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.  Highly accurate...
15.6K
Accuracy, limits, and approximation01:28

Accuracy, limits, and approximation

Accuracy, limits, and approximations are common in many fields, especially in engineering calculations. These concepts are imperative for ensuring that a given value is as close as possible to its true value.
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
1.3K