Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Effects of Percutaneous LVAD Support on Right Ventricular Load and Adaptation
Jeffrey P Yourshaw1, Prabodh Mishra2, M Christopher Armstrong2
1Division of Cardiology, Department of Medicine, Medical University of South Carolina, 114 Doughty Street, MSC 592, BM222, Charleston, 29425, USA.
Abstract:
Both operative and hemodynamic mechanisms have been implicated in right heart failure (RHF) following surgical left ventricular assist device (LVAD) implantation. We investigated the effects of percutaneous LVAD (pLVAD; Impella®, Abiomed) support on right ventricular (RV) load and adaptation. We reviewed all patients receiving a pLVAD for cardiogenic shock at our institution between July 2014 and April 2017, including only those with pre- and post-pLVAD invasive hemodynamic measurements. Hemodynamic data was recorded immediately prior to pLVAD implantation and up to 96 h post-implantation. Twenty-five patients were included. Cardiac output increased progressively during pLVAD support. PAWP improved early post-pLVAD but did not further improve during continued support. Markers of RV adaptation (right ventricular stroke work index, right atrial pressure (RAP), and RAP to pulmonary artery wedge pressure ratio (RAP:PAWP)) were unchanged acutely implant but progressively improved during continued pLVAD support. Total RV load (pulmonary effective arterial elastance; EA) and resistive RV load (pulmonary vascular resistance; PVR) both declined progressively. The relationship between RV load and RV adaptation (EA/RAP and EA/RAP:PAWP) was constant throughout. Median vasoactive-inotrope score declined after pLVAD placement and continued to decline throughout support. Percutaneous LVAD support in patients with cardiogenic shock did not acutely worsen RV adaptation, in contrast to previously described hemodynamic effects of surgically implanted durable LVADs. Further, RV load progressively declined during support, and the noted RV adaptation improvement was load-dependent as depicted by constant EA/RA and EA/RAP:PAWP relationships. These findings further implicate the operative changes associated with surgical LVAD implantation in early RHF following durable LVAD.
Related Concept Videos
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...
Impact Loading
In cases of elastic deformation,...
Distributed Loads
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...