Related Experiment Video
Updated: Feb 11, 2026

The Multiple Sclerosis Performance Test MSPT: An iPad-Based Disability Assessment Tool
Published on: June 30, 2014
Measurement of Whole-Brain and Gray Matter Atrophy in Multiple Sclerosis: Assessment with MR Imaging
Loredana Storelli1, Maria A Rocca1, Elisabetta Pagani1
1From the Neuroimaging Research Unit (L.S., M.A.R., E.P., M.F.) and Department of Neurology, Institute of Experimental Neurology, Division of Neuroscience (M.A.R., M.F.), San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Via Olgettina 60, 20132 Milan, Italy; Department of Research and Development, Icometrix, Leuven, Belgium (W.V.H., D. Sima, D. Smeets); Xinapse Systems, Colchester, England (M.A.H.); Department of Medicine, Surgery and Neuroscience, University of Siena, Siena, Italy (N.D.S.); Section of Neuroradiology, Department of Radiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain (A.R.); Unit of Clinical Neuroimmunology, CEM-Cat, Hospital Universitari Vall d'Hebron, Barcelona, Spain (J.S.G.); and Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, England (J.P.).
Abstract:
Purpose To compare available methods for whole-brain and gray matter (GM) atrophy estimation in multiple sclerosis (MS) in terms of repeatability (same magnetic resonance [MR] imaging unit) and reproducibility (different system/field strength) for their potential clinical applications. Materials and Methods The softwares ANTs-v1.9, CIVET-v2.1, FSL-SIENAX/SIENA-5.0.1, Icometrix-MSmetrix-1.7, and SPM-v12 were compared. This retrospective study, performed between March 2015 and March 2017, collected data from (a) eight simulated MR images and longitudinal data (2 weeks) from 10 healthy control subjects to assess the cross-sectional and longitudinal accuracy of atrophy measures, (b) test-retest MR images in 29 patients with MS acquired within the same day at different imaging unit field strengths/manufacturers to evaluate precision, and (c) longitudinal data (1 year) in 24 patients with MS for the agreement between methods. Tissue segmentation, image registration, and white matter (WM) lesion filling were also evaluated. Multiple paired t tests were used for comparisons. Results High values of accuracy (0.87-0.97) for whole-brain and GM volumes were found, with the lowest values for MSmetrix. ANTs showed the lowest mean error (0.02%) for whole-brain atrophy in healthy control subjects, with a coefficient of variation of 0.5%. SPM showed the smallest mean error (0.07%) and coefficient of variation (0.08%) for GM atrophy. Globally, good repeatability (P > .05) but poor reproducibility (P < .05) were found for all methods. WM lesion filling technique mainly affected ANTs, MSmetrix, and SPM results (P < .05). Conclusion From this comparison, it would be possible to select a software for atrophy measurement, depending on the requirements of the application (research center, clinical trial) and its goal (accuracy and repeatability or reproducibility). An improved reproducibility is required for clinical application. © RSNA, 2018 Online supplemental material is available for this article.
Related Concept Videos
Classifying Matter by State
Physical and Chemical Properties of Matter
The Atomic Theory of Matter
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
What is Matter?
States of Matter
Scientists have discovered a fourth state of matter, plasma, that occurs naturally in the interiors...

