Related Experiment Video
Updated: Feb 11, 2026

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Emergency and critical care applications for contrast-enhanced ultrasound
Tobias Kummer1, Laura Oh2, Mary Beth Phelan3
1Department of Emergency Medicine, Mayo Clinic, Rochester, MN, United States.
Introduction:
Contrast-enhanced ultrasound (CEUS) using intravascular microbubbles has potential to revolutionize point-of-care ultrasonography by expanding the use of ultrasonography into clinical scenarios previously reserved for computed tomography (CT), magnetic resonance imaging, or angiography.
Methods:
We performed a literature search and report clinical experience to provide an introduction to CEUS and describe its current applications for point-of-care indications.
Results:
The uses of CEUS include several applications highly relevant for emergency medicine, such as solid-organ injuries, actively bleeding hematomas, or abdominal aortic aneurysms. Compared with CT as the preeminent advanced imaging modality in the emergency department, CEUS is low cost, radiation sparing, repeatable, and readily available. It does not require sedation, preprocedural laboratory assessment, or transportation to the radiology suite.
Conclusions:
CEUS is a promising imaging technique for point-of-care applications in pediatric and adult patients and can be applied for patients with allergy to CT contrast medium or with impaired renal function. More high-quality CEUS research focusing on accuracy, patient safety, health care costs, and throughput times is needed to validate its use in emergency and critical care settings.
Related Concept Videos
Applications of GIS: Disaster Management and Emergency Response
Emerging Adulthood
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Introduction Cardiac Emergencies

