Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Noninvasive Blood Pressure Monitoring and Prediction of Fluid Responsiveness to Passive Leg Raising
Joya D Pickett1, Elizabeth Bridges2, Patricia A Kritek2
1Joya D. Pickett is a critical care clinical nurse specialist at Swedish Medical Center, Seattle, Washington. Elizabeth Bridges is a professor at University of Washington School of Nursing and a clinical nurse researcher at University of Washington Medical Center, University of Washington Medicine, Seattle, Washington. Patricia A. Kritek is medical director of critical care and an associate professor in the Division of Pulmonary and Critical Care Medicine at University of Washington Medical Center. JoAnne D. Whitney is a professor at the University of Washington School of Nursing and endowed professor in critical care nursing at Harborview Medical Center, University of Washington Medicine. joyap@u.washington.edu.
Background:
Intravenous fluid boluses are administered to patients in shock to improve tissue hypoperfusion. However, fluid boluses result in clinically significant stroke volume increases in only about 50% of patients. Hemodynamic responses to passive leg raising measured with invasive and minimally invasive methods are accurate predictors of fluid responsiveness. However, few studies have used noninvasive blood pressure measurement to evaluate responses to passive leg raising.
Objective:
To determine if passive leg raising-induced increases in pulse pressure or systolic blood pressure can be used to predict clinically significant increases in stroke volume index in healthy volunteers.
Methods:
In a repeated-measures study, hemodynamic measurements were obtained in 30 healthy volunteers before, during, and after passive leg raising. Each participant underwent the procedure twice.
Results:
In the first test, 20 participants (69%) were responders (stroke volume index increased by ≥ 15%); 9 (31%) were nonresponders. In the second test, 15 participants (50%) were responders and 15 (50%) were nonresponders. A passive leg raising-induced increase in pulse pressure of 9% or more predicted a 15% increase in stroke volume index (sensitivity, 50%; specificity, 44%). There was no association between passive leg raising-induced changes in systolic blood pressure and fluid responsiveness.
Conclusion:
A passive leg raising-induced change in stroke volume index measured by bioreactance differentiated fluid responders and nonresponders. Pulse pressure and systolic blood pressure measured by oscillometric noninvasive blood pressure monitoring were not sensitive or specific predictors of fluid responsiveness in healthy volunteers.
More Related Videos
Related Concept Videos
Assessing Blood pressure in the Leg
Preparation:
Errors occurring during blood pressure monitoring
Several factors...
Pressure of Fluids
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Vapor Pressure of Fluid
When a liquid is placed in a closed container with a small air space, and the space is evacuated, vapor molecules will...