Related Experiment Video
Updated: Feb 11, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Percutaneous Renal Biopsy: Comparison of Blind and Real-time Ultrasound Guided Technique
Anil Pokhrel1, Rajendra Kumar Agrawal1, Anil Baral1
1Department of Nephrology, National Academic of Medical Sciences, Bir Hospital, Kathmandu, Nepal.
Background:
Percutaneous renal biopsy is performed for diagnosis and prediction of prognosis of renal diseases. Adequacy of tissue and clinically significant bleeding are the main issues of the procedure. We aimed to compare these issues in renal biopsy by blind and real time ultrasound guided technique.
Methods:
It was a cross sectional, randomized study conducted between June 2016 to December 2016. In blind technique, marking for biopsy was done by ultrasound. Two attempts were performed for all and more if tissue was inadequate. Patients kept in bed rest for 24 hours, observed for post procedure hematuria and ultrasound done at 6 hours and 24 hours to diagnose perinephric hematoma.
Results:
Total 75 biopsies (blind = 37 and Ultrasound -guided = 38) were evaluated. Blind and Ultrasound-guided technique had significant difference of number of attempt (mean±SD) 2.4±0.6 and 2.1±0.3 (p<0.01) respectively with no difference of number of glomeruli in light microscopy. Bleeding complications were macroscopic hematuria (11(30%)vs15(40%)) and perinephric hematoma ( 5(13.5%)vs3(7.9%)) in blind and Ultrasound-guided technique respectively with no significant difference. Those patients who developed perinephric hematoma was observed in all at 6 hours.
Conclusions:
Ultrasound-guided technique of percutaneous renal biopsy is superior with fewer attempts and equivalent in adequacy of tissue and bleeding complication than blind technique.
More Related Videos
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Blind Procedures
Blinding
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Voltammetric Techniques: Linear-Scan (E vs Time)