Feasibility and agreement of stiffness measurements using gradient-echo and spin-echo MR elastography sequences in
Guilherme Moura Cunha1, Kevin J Glaser2, Anke Bergman3
11 MRI Department, Clínica de Diagnóstico por Imagem CDPI-DASA , Rio de Janeiro , Brazil.
Objective:
To evaluate the agreement of three MR elastography (MRE) sequences in patients undergoing liver MRI for clinical care. Methods: A cross-sectional retrospective study was performed with 223 patients referred for liver MRI, including 12 patients with liver iron overload. Data obtained with spin-echo (SE) and gradient-echo (GRE) MRE sequences were compared. Multiple linear regression adjusted for the presence of liver fat was also performed to assess the correlation between fat infiltration and stiffness measurements results. Agreement between two SE sequences was assessed in patients with liver iron overload. Results: We found strong correlation between the GRE sequence and two SE sequences. Spearman's correlation coefficients between the GRE, SE, and SE-EPI MRE sequences in patients with liver R2* <75Hz were 0.74, 0.81, and 0.80. GRE-MRE failed in patients with liver R2* > 75 Hz. In this subgroup, the correlation coefficient between both SE-MRE sequences was 0.97. Liver fat did not interfere with the results.
Conclusion:
In clinical setting, there is a high correlation between the GRE and SE MRE stiffness measurements, independently of the degree of liver fat infiltration measured by PDFF. A strong correlation between SE-MRE sequences is found even in patients with iron overload. Advances in knowledge: Our study addresses liver iron and fat content simultaneously to describing the technical feasibility and correlation between different MRE sequences in consecutive unselected patients refereed for liver MRI. EPI SE-MRE should be considered an optimal alternative to assess liver fibrosis in patients in whom GRE-MRE failures, such as iron-overloaded, in pediatric, elderly, or severely ill populations.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
NMR Spectroscopy: Spin–Spin Coupling
Spin–Spin Coupling: One-Bond Coupling
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...