Related Experiment Video
Updated: Feb 11, 2026

Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
Association of Lower Limb Compression Garments During High-Intensity Exercise with Performance and Physiological
César Augusto da Silva1,2, Lucas Helal1,3, Roberto Pacheco da Silva1,4
1Graduate Program in Cardiology and Cardiovascular Sciences, School of Medicine, Hospital de Clínicas de Porto Alegre (HCPA), Universidade Federal do Rio Grande do Sul (UFRGS), Térreo, Ramiro Barcelos 2350, Largo Eduardo Zaccaro Faraco, Porto Alegre, RS, CEP 90035-903, Brazil.
Background:
Although compression garments are used to improve sports performance, methodological approaches and the direction of evidence regarding garments for use in high-intensity exercise settings are diverse.
Objectives:
Our primary aim was to summarize the association between lower-limb compression garments (LLCGs) and changes in sports performance during high-intensity exercise. We also aimed to summarize evidence about the following physiological parameters related to sports performance: vertical jump height (VJ), maximal oxygen uptake (VO2max), submaximal oxygen uptake (VO2submax), blood lactate concentrations ([La]), and ratings of perceived exertion (RPE, 6-20 Borg scale).
Methods:
We searched electronic databases (PubMed, EMBASE, Cochrane Library, and ClinicalTrials.gov) and reference lists for previous reviews. Eligible studies included randomized controlled trials with athletes or physically active subjects (≥ 18 years) using any type of LLCG during high-intensity exercise. The results were described as weighted mean difference (WMD) with a 95% confidence interval (95% CI).
Results:
The 23 included studies showed low statistical heterogeneity for the pooled outcomes. We found that LLCGs yielded similar running performance to controls (50-400 m: WMD 0.06 s [95% CI - 1.99 to 2.11]; 800-3000 m: WMD 6.10 s [95% CI - 7.23 to 19.43]; > 5000 m: WMD 1.01 s [95% CI - 84.80 to 86.82]). Likewise, we found no evidence that LLCGs were superior in secondary outcomes (VJ: WMD 2.25 cm [95% CI - 2.51 to 7.02]; VO2max: WMD 0.24 mL.kg-1.min-1 [95% CI - 1.48 to 1.95]; VO2submax: WMD - 0.26 mL.kg-1.min-1 [95% CI - 2.66 to 2.14]; [La]: WMD 0.19 mmol/L [95% CI - 0.22 to 0.60]; RPE: WMD - 0.20 points [95% CI - 0.48 to 0.08]).
Conclusions:
LLCGs were not associated with improved performance in VJ, VO2max, VO2submax, [La], or RPE during high-intensity exercise. Such evidence should be taken into account when considering using LLCGs to enhance running performance.
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
08:39Fabrication of Compressed Hosiery and Measurement of its Pressure Characteristic Exerted on the Lower Limbs
Published on: May 27, 2020
Related Concept Videos
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Random and Systematic Errors
Directing Effect of Substituents: meta-Directing Groups