Related Experiment Video
Updated: Feb 11, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Ultrasound-guided central venous tip confirmation via right external jugular vein using a right supraclavicular fossa
Mariko Kosaka1, Yoshimasa Oyama1, Tetsuya Uchino1
1Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, Oita University, Yufu City, Japan.
Introduction::
Ultrasound-guided central venous catheter tip confirmation has a potential to precisely locate the central venous catheter, preventing its misplacement, using real-time guidance. This observational study sought to determine the accuracy of central venous catheter tip positioning via the external jugular vein via a supraclavicular fossa view under ultrasound guidance.
Methods::
In total, 77 patients scheduled for central venous catheter insertion via the right external jugular vein were enrolled. The depth of central venous catheter insertion was determined by advancing the tip of the guidewire to the junction of the superior vena cava and right pulmonary artery, using a right supraclavicular fossa view ultrasound method. We determined the reference insertion depth to the carina using a postoperative chest x-ray photograph method. We then compared insertion depths obtained by the ultrasound and x-ray photograph methods and body-height formula.
Results::
In total, 62 patients were able to advance the guidewire and underwent ultrasound-guided central venous catheter insertion. In four patients, we corrected for misplaced guidewires. According to Bland-Altman plots, the insertion depth was 0.88 cm shorter for the ultrasound method (95% limits of agreement, -1.66 to 3.41 cm) and 0.90 cm shorter for the formulaic method (95% limits of agreement, -2.77 to 4.56 cm), compared with the x-ray photograph method. The x-ray photograph method had significantly positive correlations with the ultrasound (r = 0.73) and formulaic methods (r = 0.27).
Conclusion::
A right supraclavicular fossa view improves the accuracy of central venous catheter tip positioning and prevents central venous catheter misplacement via the right external jugular vein.
More Related Videos
08:27Adult Mouse Venous Hypertension Model: Common Carotid Artery to External Jugular Vein Anastomosis.
Published on: January 27, 2015
15:21Training a Sophisticated Microsurgical Technique: Interposition of External Jugular Vein Graft in the Common Carotid Artery in Rats
Published on: November 11, 2012
Related Concept Videos
Confirmation Biases
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
The Central Dogma
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Econometric Views (EViews)
Measures of Central Tendency