Cardiac output measurement in liver transplantation patients using pulmonary and transpulmonary thermodilution: a
Luigi Vetrugno1, Elena Bignami2, Federico Barbariol3
1Anesthesiology and Intensive Care Clinic, Department of Medicine, University of Udine, P.le S. Maria della Misericordia n.15, 33100, Udine, Italy. luigi.vetrugno@asuiud.sanita.fvg.it.
Abstract:
During liver transplantation surgery, the pulmonary artery catheter-despite its invasiveness-remains the gold standard for measuring cardiac output. However, the new EV1000 transpulmonary thermodilution calibration technique was recently introduced into the market by Edwards LifeSciences. We designed a single-center prospective observational study to determine if these two techniques for measuring cardiac output are interchangeable in this group of patients. Patients were monitored with both pulmonary artery catheter and the EV1000 system. Simultaneous intermittent cardiac output measurements were collected at predefined steps: after induction of anesthesia (T1), during the anhepatic phase (T2), after liver reperfusion (T3), and at the end of the surgery (T4). The 4-quadrant and polar plot techniques were used to assess trending ability between the two methods. We enrolled 49 patients who underwent orthotopic liver transplantation surgery. We analyzed a total of 588 paired measurements. The mean bias between pulmonary artery catheter and the EV1000 system was 0.35 L/min with 95% limits of agreement of - 2.30 to 3.01 L/min, and an overall percentage error of 35%. The concordance rate between the two techniques in 4-quadrant plot analysis was 65% overall. The concordance rate of the polar plot showed an overall value of 83% for all pairs. In the present study, in liver transplantation patients we found that intermittent cardiac output monitoring with EV1000 system showed a percentage error compared with pulmonary artery catheter in the acceptable threshold of 45%. On the others hand, our results showed a questionable trending ability between the two techniques.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...