Related Experiment Video
Updated: Feb 11, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Qualitative Assessment of Reliability of Cone-beam Computed Tomography in evaluating Bone Density at Posterior
Kirti Dahiya1, Narendra Kumar2, Pankaj Bajaj3
1Department of Prosthodontics, Institute of Dental Studies & Technologies, Modinagar, Uttar Pradesh, India, Phone: +917417240511,
Abstract:
Introduction: The success of dental implants depends primarily on the primary implant stability and the bone density so that predictable osseointegration can be achieved. To achieve the desired results, systematic preoperative planning for implant placement is required. The sole aim of the study was to assess the reliability of preoperative bone density of mandibular posterior region for implant placement using computerized tomography-derived bone densities in Hounsfield units (HU). Materials and methods: A total of 200 patients with 352 implant sites between 2014 and 2017 were assessed for the posterior mandibular area using cone-beam computed tomography (CBCT). Evaluation was done by two experienced observers independently. Results: The mean bone density of males was 690.5 ± 104.12 HU and in females, it was 580.20 ± 120.2 HU. Overall, 21% of sites were of low bone density, 39.5% were of intermediate density, and 39.4% were of high density. Receiver operating characteristic (ROC) analysis presented that the CBCT intensity values had a high predictive power for predicting both high-density sites and intermediate-density sites. Conclusion: We can say from our results that, for predicting the bone densities in posterior mandible for determining implant sites, so as to achieve best osseointegration, CBCT values can be reliably used. Clinical significance: It has been proved that bone density and implant stability are dependent on each other and osseointegration is important for the success of treatment. With advancements in dentistry and introduction of CBCT, treatment planning and prediction of appropriate implant sites could be made easy and more predictable. Thus, we can say that CBCT can be considered an alternative diagnostic tool for the bone density evaluation during treatment planning for implant placement. Keywords: Bone density, Cone-beam computed tomography, Implants, Osseointegration.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Cranial Bones: Superior and Posterior View
The frontal bone is the single bone that forms the forehead. At its anterior midline, between the eyebrows, there is a slight depression called the glabella. The frontal bone also forms the supraorbital margin of the orbit. Near the middle of this margin is the supraorbital foramen, the opening that provides passage for a sensory nerve to the forehead. The frontal bone is thickened just above each supraorbital margin,...
Imaging Studies III: Computed Tomography
Qualitative Analysis
For instance, group IV...
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Reliability and Validity