Anxiety and feedback processing in a gambling task: Contributions of time-frequency theta and delta

Jessica S Ellis1, Adreanna T M Watts1, Norman Schmidt2

  • 1University of Maryland, College Park, United States.

Related Concept Videos

The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.2K
Feedback Inhibition00:46

Feedback Inhibition

Biochemical reactions are occurring constantly in cells, converting starting substances to different products, usually with the help of enzymes that speed the reactions. Without enzymes, it would take far too long for most reactions to occur to be useful to the cell!
57.3K
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
719
The Delta-to-Y Circuit01:16

The Delta-to-Y Circuit

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
891
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
439