Related Experiment Video
Updated: Feb 11, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Randomized study of percutaneous ureteroscopic plasma column electrode decortication and laparoscopic decortication
Weiguang Liu1, Chengrong Zhang2, Bohan Wang3
1Department of Urology, The Affiliated Hospital, Weifang Medical University, Weifang 261031, China.
Background:
To assess the safety and efficacy of a novel technology referred to as percutaneous ureteroscopic plasma column electrode (PCE) by comparing laparoscopic decortication in the management of simple renal cyst (SRC).
Methods:
Between March 2016 and June 2017, 53 patients with SRCs were randomized to divided into two groups, the PCE group (24 patients), or laparoscope group (29 patients). The operative time, blood loss, days of drainage, catheter, and hospital stay and complications were compared with the two groups. All patients were followed- up to 6 months after treatment.
Results:
No patients had intraoperative complications such as hemopneumothorax, adjacent organ injury, infection or hemorrhage shock. In the PCE group and laparoscope group: the mean operation time was 34.1±8.2 vs. 58.4±16.7 min (P<0.05). The mean blood loss was 2.0±1.16 vs. 9.7±4.09 mL (P<0.05). The mean postoperative indwelling drainage tube time was 2.5±1.5 vs. 2.9±1.09 d (P>0.05). The mean intra-urethral indwelling catheter time was 2.1±0.88 vs. 2.0±1.15 d (P>0.05). The mean postoperative hospital stay was 3.0±1.7 vs. 3.7±1.53 (P>0.05). One patient in electrode group was suffered from rupture of the collecting system during the operation, and was treated by indwelling D-J stent. During follow up, no cysts recurrence was found.
Conclusions:
Percutaneous ureteroscopic PCE decortication is a safe, minimally invasive and effective therapy to treat SRCs, with equal efficacy and advantages in shortening the operation time and reducing the amount of intraoperative bleeding compared with laparoscopic decortication.
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...
Serum Studies: Renal Function Tests
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Acute Pyelonephritis II: Diagnostic Studies and Management
Random Error