Minimum ten-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and
Kotryna Veresciagina1, Arne Mehrkens1, Stefan Schären1
1Department of Clinic for Musculoskeletal Disease/Spine, University Hospital, Basel, Switzerland.
Background:
The Dynesys system remains the most widely implanted posterior non-fusion pedicle screw system. Various study designs used in investigations with good to excellent short- and mid-term results have been reported in the current literature. However, there is a lack of information concerning long-term outcomes following treatment for spinal stenosis with degenerative spondylolisthesis.
Methods:
The aim of our study was twofold. Firstly, to assess whether the dynamic stabilization in situ with the Dynesys System without bone grafting provides enough stability to prevent progression of spondylolisthesis and secondarily to maintain significant clinical improvement in a long-term follow-up (FU). Therefore, the consecutive patients due to inclusion criterions underwent interlaminar decompression and stabilization with Dynesys instrumentation. Patients were evaluated clinically and radiologically after a minimum FU of 10 years.
Results:
At FU, the mean low back pain (LBP) post-operatively and leg pain (LP) post-operatively on visual analog scale (VAS) and North American Spine Society (NASS) improved significantly (P<0.001) compared to preoperative examination. The mean value of NASS neurogenic symptoms (19.13% and 4.72%) and activity subscores were 23.13% and 10.74% respectively. In plain and functional radiographs the mean listhesis grade in neutral position was 11.11%, 11.8% in reclination and 11.63% in inclination. There were 17 and 8 patients with progressing degenerative osteochondrosis/listhesis at adjacent segments.
Conclusions:
Decompression and single and double level dynamic in situ stabilization with the Dynesys System demonstrate good clinical and radiological long-term results in elderly patients.
Related Concept Videos
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Mitral Stenosis I: Introduction
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Stability of structures
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...