Related Experiment Video
Updated: Feb 11, 2026

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Tracheobronchial angles in children: Three-dimensional computed tomography-based measurements.
Tariq M Wani1,2, Basharat Buchh3, Faris Saeed AlGhamdi2
1Department of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH, USA.
Tracheobronchial angles in children under 8 are nearly identical between the right and left main bronchi. This study using 3D CT scans found no significant age-related differences in these pediatric airway measurements.
Area of Science:
- Pediatric radiology
- Anatomy
- Medical imaging
Background:
- Significant variations in tracheobronchial angles exist in pediatric patients.
- Accurate 3D computed tomography (CT) imaging is crucial for understanding pediatric airway anatomy.
Purpose of the Study:
- To measure right and left bronchial angles in children using 3D CT scans.
- To clarify understanding of tracheobronchial angles in pediatric populations.
Main Methods:
- Reviewed 3D CT scans of 45 children under 8 years old.
- Calculated bronchial angles using the central axes of bronchi and trachea.
- Analyzed angle differences and age dependence using statistical tests.
Main Results:
- Right bronchial angle: 42° ± 7° (range 23°-56°).
- Left bronchial angle: 43° ± 9° (range 25°-68°).
- No statistically significant difference between right and left bronchial angles (P = .282); no age association found.
Conclusions:
- Right and left bronchial angles are virtually identical in children up to 8 years old.
- The difference between these angles does not vary with age in this pediatric cohort.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
11:09Construction of a Realistic, Whole-Body, Three-Dimensional Equine Skeletal Model using Computed Tomography Data
Published on: February 25, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Traverse Angle Computations
Imaging Studies III: Computed Tomography
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...