Effects of Cochlear Implantation on Binaural Hearing in Adults With Unilateral Hearing Loss
Emily Buss1, Margaret T Dillon1, Meredith A Rooth1
11 Department of Otolaryngology/Head and Neck Surgery, 2331 University of North Carolina School of Medicine , Chapel Hill, NC, USA.
Abstract:
A FDA clinical trial was carried out to evaluate the potential benefit of cochlear implant (CI) use for adults with unilateral moderate-to-profound sensorineural hearing loss. Subjects were 20 adults with moderate-to-profound unilateral sensorineural hearing loss and normal or near-normal hearing on the other side. A MED-EL standard electrode was implanted in the impaired ear. Outcome measures included: (a) sound localization on the horizontal plane (11 positions, -90° to 90°), (b) word recognition in quiet with the CI alone, and (c) masked sentence recognition with the target at 0° and the masker at -90°, 0°, or 90°. This battery was completed preoperatively and at 1, 3, 6, 9, and 12 months after CI activation. Normative data were also collected for 20 age-matched control subjects with normal or near-normal hearing bilaterally. The CI improved localization accuracy and reduced side bias. Word recognition with the CI alone was similar to performance of traditional CI recipients. The CI improved masked sentence recognition when the masker was presented from the front or from the side of normal or near-normal hearing. The binaural benefits observed with the CI increased between the 1- and 3-month intervals but appeared stable thereafter. In contrast to previous reports on localization and speech perception in patients with unilateral sensorineural hearing loss, CI benefits were consistently observed across individual subjects, and performance was at asymptote by the 3-month test interval. Cochlear implant settings, consistent CI use, and short duration of deafness could play a role in this result.
Related Concept Videos
Hearing
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...