Related Experiment Video
Updated: Feb 11, 2026

Murine Renal Transplantation Procedure
Published on: July 10, 2009
Reliability of serum creatinine-based formulae estimating renal function in non-critically ill surgery patients:
Peter Declercq1, Matthias Gijsen2, Björn Meijers3
1Department of Pharmaceutical and Pharmacological Sciences, Clinical Pharmacology and Pharmacotherapy, Universitaire Ziekenhuizen Leuven, Leuven, Belgium.
What Is Known And Objectives:
Formulae estimating glomerular filtration rate (GFR) are frequently used to guide drug dosing. The objectives of this prospective single-center study were to evaluate agreement between these equations and measured creatinine clearance (CrCl) in non-critically ill surgery patients with normal kidney function and augmented renal clearance (ARC, CrCl ≥ 130 mL/min/1.73 m²), to determine predictors for disagreement, define a GFR estimator cut-off value identifying ARC and determine the ARC prevalence and duration in non-critically ill surgical patients.
Methods:
Hospitalized adult non-critically ill abdominal and trauma surgery patients were eligible for inclusion. Measured CrCl based on an 8-hour urinary collection (CrCl8h ) was used as the primary method for determining kidney function. Agreement between equations and measured CrCl8h was assessed in terms of precision, defined as a bias within ±10 mL/min/1.73 m². Predictors for disagreement were identified for the most precise estimator using an ordinal logistic regression model with negative bias, agreement and positive bias as outcome variables. A receiver operating characteristic (ROC) analysis was performed to identify an estimator cut-off predicting ARC, which was subsequently applied for the daily proportion of patients displaying ARC and ARC duration.
Results And Discussion:
During the study period (14/11/2013 - 13/05/2014), in 232 adult non-critically ill abdominal and trauma surgery patients, all estimators tend to underestimate CrCl8h (mean bias ranging from 17 to 22 mL/min/1.73 m²), especially in patients displaying ARC (mean bias ranging from 44 to 56 mL/min/1.73 m²). eGFRCKD-EPI performed the best. Younger age and low ASA score independently predicted underestimation of CrCl8h . Three different eGFRCKD-EPI cut-offs with decreasing sensitivity and increasing specificity (84, 95 and 112 mL/min/1.73 m²) identified, respectively, 65%, 44% and 14% patients displaying ARC. The median ARC duration was 4, 4 and 3 days, respectively.
What Is New And Conclusion:
In surgical patients, eGFR frequently underestimates measured CrCl, especially in young patients with low ASA score. eGFR cut-offs predicting ARC were identified.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Serum Studies: Renal Function Tests
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...

