A Column-Row-Parallel Ultrasound Imaging Architecture for 3-D Plane-Wave Imaging and Tx Second-Order Harmonic
Abstract:
We propose a column-row-parallel imaging front-end architecture for integrated and low-power 3-D medical ultrasound imaging. The column-row-parallel architecture offers linear-scaling interconnection, acquisition, and programming time with row-by-row or column-by-column operations, while supporting volumetric imaging functionality and fault-tolerance against possible transducer element defects with per-element controls. The combination of column-parallel selection logic, row-parallel selection logic, and per-element selection logic reaches a balance between flexible imaging aperture definition and manageable imaging data/control interface to a 2-D array. A capacitive micromachined ultrasonic transducer (CMUT)-application-specific integrated circuit (ASIC) column-row-parallel prototype is fabricated and assembled with a flip-chip bonding process. It facilitates the 3-D plane-wave coherent compounding algorithm for volumetric imaging with a fast frame rate of 62.5 Hz and 46% improved lateral resolution with 10-angle compounding and a field of view volume of 2.3 mm in both azimuth and elevation, 8.5 mm in depth. At a hypothetically scaled up array size, the frame rate can still be kept at 31.2 Hz for a volume of 40 mm in both azimuth and elevation, 150 mm in depth. An interleaved checkerboard pattern with in-phase ( ) and quadrature ( ) excitations is also demonstrated for reducing CMUT second-harmonic distortion emission by up to 25 dB at the loss of 3-dB fundamental energy reduction. The method reduces nonlinear effects from both transducers and circuits and is a wide band technique that is applicable to arbitrary pulse shapes.
More Related Videos
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
08:21Wideband Optical Detector of Ultrasound for Medical Imaging Applications
Published on: May 11, 2014
Related Concept Videos
Plane Electromagnetic Waves I
The EM field is assumed to be a...
Plane Electromagnetic Waves II
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
The Wave Nature of Light
Oxidation-Reduction Reactions
Parallel Processing