Noninvasive Measures of Pulsatility and Blood Pressure During Continuous-Flow Left Ventricular Assist Device Support
Sabarivinoth Rangasamy1, Shivank Madan1, Omar Saeed1
1From the Division of Cardiology, Department of Medicine, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York.
Abstract:
The reliability and validity of a palpable pulse and other noninvasive measures of pulsatility in patients on continuous-flow (CF) left ventricular assist device (LVAD) support have not been rigorously evaluated. We prospectively enrolled 23 patients who had CF-LVAD and an arterial catheter for blood pressure (BP) monitoring. Pulse pressure (PP) via the arterial line was compared with three noninvasive measures of pulsatility: presence of a palpable pulse, pulsatility index (PI), and aortic valve opening (AVO). In addition, the relationship between Doppler BP (DopBP) and arterial line pressures was evaluated. The study group comprised 30% females, 73% nonischemic cardiomyopathy, 87% axial flow device (HeartMate II [HMII]), and 13% centrifugal flow device (HeartWare ventricular assist device [HVAD]) support. Among four practitioners, the interobserver agreement for the presence of a palpable pulse was moderate (k = 0.41; 95% CI, 0.28-0.60). If the PP was ≥15 mm Hg, a radial pulse was palpated 82% of the time, whereas when the PP was <15 mm Hg, a radial pulse was palpated only 35% of the time. In subjects with a palpable pulse, there was a strong correlation between DopBP and systolic BP (SBP) (r = 0.94; 95% CI, 0.82-0.99), whereas the correlation between DopBP and mean arterial pressure (MAP) was much weaker (r = 0.42; 95% CI, 0.19-0.96). In subjects without a palpable pulse, there was a strong correlation between both the DopBP and SBP (r = 0.94; 95% CI, 0.80-1.0) and DopBP and MAP (r = 0.87; 95% CI, 0.77-1.00). Finally, PP was significantly associated with PI (odds ratio [OR], 0.3; 95% CI, 0.14-0.45; p = 0.0002) but not AVO (OR, 1.41: 95% CI, 0.70-2.83; p = 0.33). The presence of a palpable pulse has good interobserver agreement and allows for dichotomization of the DopBP to reflect the SBP in its presence and the MAP in its absence. This simple measure should be incorporated into BP management algorithms for CF-LVADs. The PI shows a modest correlation to PP.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...