Related Experiment Video
Updated: Feb 11, 2026

A New Technique for Treating Low-risk Prostate Cancer—Super Active Surveillance
Published on: November 7, 2025
A thermal protective urethral heater applied to modulate the prostate cryoablation area
1Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry and MolecularEngineering, East China University of Science and Technology, Shanghai, China.
Background:
Urethral warmer and cryoheater are invented and applied in cryoablation to overcome urethral cryoinjury, but these devices cannot be fixed and precisely control the released heat which excessively reduces the effective ablation area. Current warmers enlarge the operation difficulty and decrease the precision in temperature control.
Objective:
A reformed catheter termed urethral heater aims to protect the urethra and simultaneously control the released heat so as to meet the aid of doctors' convenient operation in effective therapy, device fixation and precise heat controllability.
Materials And Methods:
In this paper, the temperature controller combined with temperature monitor was used to control the heating behavior of the urethral heater with the initial active temperature. The controllability and thermal protection of the urethral heater was simulated and tested, which compared with that of urethral warmer.
Results:
During the trials in vitro, the lowest temperature at the urethra surface is -3.7 degree C when one cryoprobe was introduced in the cryoablation for 15 min and -15.3 degree C with two cryoprobes. Above all, the effective cryoablation area increased with the decline of initial active temperatures.
Conclusion:
The urethral heater is able to prevent the urethra from irreversible damage and modulate the ablation area. The delay of heat is a new way to decline the recurrence rate and facilitate the desire of aconuresis during the cryoablation.
Related Concept Videos
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Thermal Strain

