Related Experiment Video
Updated: Feb 11, 2026

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Assessment of air passive sampling uptakes for volatile organic compounds using VERAM devices
Thalita Dallapícula Ramos1, Miguel de la Guardia2, Agustín Pastor2
1Department of Analytical Chemistry, University of Valencia, Jeroni Muñoz Building, 50th Dr. Moliner St., 46100 Burjassot, Spain; Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Niterói, RJ 24020-141, Brazil.
Abstract:
A calibration chamber has been designed and employed for the simple and easy determination of uptake sampling rate (RS) of volatile organic compounds (VOCs) from air using passive samplers. A flow of clean air was continuously spiked, at a constant VOC concentration, by the microinjection of a standard solution by means of a T-type tube. The developed system allowed the complete evaporation at room temperature of the standard solution in acetone and the air concentration of VOCs was easily controlled by the regulation of the clean air flow, the standard solution concentration and its flow. Active sampling was employed for monitoring the true concentration of the evaluated compounds inside the calibration chamber, using Tenax-filled desorption tubes and a low flow personal air sampling pump. Versatile, easy and rapid atmospheric monitor (VERAM) devices were employed for the passive sampling of benzene, toluene, ethylbenzene, xylenes, α-pinene, camphene, myrcene, p-cymene, and limonene from air. The RS values obtained for the passive sampling of VOCs, using the developed calibration chamber, were in the range of 1.3-16.0m3day-1 in accordance to previous calibration studies performed for VERAM samplers. The developed calibration chamber provided a continuous flow with a constant concentration of the evaluated compounds that allowed the simultaneous deployment of several samplers for a rapid establishment of RS for a passive sampler type and the easy comparison between different devices.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Related Concept Videos
Organic Compounds
Volatilization
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Molecules and Compounds
Elements and Compounds
Elements
Elements are classified as atomic or molecular based on the nature of their basic units. They are unique forms of matter with specific chemical and physical properties that cannot break down into smaller substances by ordinary chemical reactions. There...