Related Experiment Video
Updated: Feb 11, 2026

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
On Patient Related Factors and Their Impact on Ultrasound-Based Shear Wave Elastography of the Liver
Marie Byenfeldt1, Anders Elvin2, Per Fransson2
1Department of Nursing, Umeå University, Umeå, Sweden.
Abstract:
The aim of the study was to investigate patient-related factors associated with either reliable or poorly reliable measurement results of ultrasound-based shear wave elastography (SWE) of the liver. A total of 188 patients were analyzed prospectively with binary logistic regression using the interquartile range/median as cutoff to define two groups based on reliable and poorly reliable SWE results. SWE results correlated significantly with liver biopsy. Factors associated with reliable SWE results (i.e., no negative impact on measurements) were age, sex, cirrhosis, antiviral and/or cardiovascular medication, smoking habits and body mass index. Factors associated with poorly reliable SWE results were increased skin-to-liver capsule distance (odds ratio = 3.08, 95% confidence interval: 1.70-5.60) and steatosis (odds ratio = 2.89, 95% confidence interval: 1.33-6.28). These findings indicate that the interquartile range/median as a quality parameter is useful in avoiding poorly reliable SWE results. How best to examine patients with increased skin-to-liver capsule distance is a matter of some controversy, as the incidences of obesity, diabetes and metabolic syndrome are increasing worldwide; however, our results indicate that reliable SWE results can be obtained in this group of patients by using ultrasound-based SWE.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
06:09Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
Related Concept Videos
Factors Affecting Protein-Drug Binding: Patient-Related Factors
Age stands as a key determinant in protein-drug binding. Neonates, characterized by low albumin content, experience heightened concentrations of unbound drugs such as phenytoin and...
The Wave Nature of Light
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Strain
Impact of Groups on Groups