Related Experiment Video
Updated: Feb 10, 2026

Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Improved determination of mechanical power output in rowing: Experimental results
Lotte L Lintmeijer1, Mathijs J Hofmijster1,2, Guido A Schulte Fischedick1
1a Amsterdam Movement Science , Vrije Universiteit Amsterdam , Amsterdam , The Netherlands.
Abstract:
In rowing, mechanical power output is a key parameter for biophysical analyses and performance monitoring and should therefore be measured accurately. It is common practice to estimate on-water power output as the time average of the dot product of the moment of the handle force relative to the oar pin and the oar angular velocity. In a theoretical analysis we have recently shown that this measure differs from the true power output by an amount that equals the mean of the rower's mass multiplied by the rower's center of mass acceleration and the velocity of the boat. In this study we investigated the difference between a rower's power output calculated using the common proxy and the true power output under different rowing conditions. Nine rowers participated in an on-water experiment consisting of 7 trials in a single scull. Stroke rate, technique and forces applied to the oar were varied. On average, rowers' power output was underestimated with 12.3% when determined using the common proxy. Variations between rowers and rowing conditions were small (SD = 1.1%) and mostly due to differences in stroke rate. To analyze and monitor rowing performance accurately, a correction of the determination of rowers' on-water power output is therefore required.
More Related Videos
06:10Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
11:16Engineering Platform and Experimental Protocol for Design and Evaluation of a Neurally-controlled Powered Transfemoral Prosthesis
Published on: July 22, 2014
Related Concept Videos
Experimental Determination of Chemical Formula
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Power
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...