The effect of varying cone beam computed tomography image resolution and field-of-view centralization on effective
Fatima M Jadu1, Asmaa A Alzahrani, Maha A Almutairi
1Division of Oral and Maxillofacial Radiology, Department of Oral Diagnostic Sciences, Faculty of Dentistry, King Abdulaziz University, Jeddah, Kingdom of Saudi Arabia. E-mail. fjadu@kau.edu.sa.
Objectives:
To investigate changes in the effective radiation dose (E) in relation to variations in voxel (VOX) size settings and the field-of-view (FOV) centralization. Methods: This cross-sectional dosimetry study used nanoDot OSLD dosimeters placed at 25 pre-determined sites in the head and neck slices of a RANDO male phantom to measure the absorbed radiation. The imaging scans took place at King Abdulaziz University Dental Hospital, Jeddah, Saudi Arabia between September 2016 and May 2017 using the i-CAT classic cone beam computed tomography (CBCT) unit. Three VOX size setting were examined: 0.2 mm, 0.3 mm and 0.4 mm. The FOV was alternatively eccentrically centered on the maxillary and mandibular arches while holding all other factors constant. Effective radiation doses were calculated for each VOX size and FOV centralization setting. Results: An inverse and indirect relation was found between E and the VOX size setting with smaller VOX yielding higher E. CBCT scans centered on the mandible resulted in higher E than scans centered on the maxilla. Conclusion: Effective radiation doses are significantly affected by changes in VOX size settings and FOV centralization options. This reflects on the potential radiation risk to patients and highlights the importance of choosing exposure parameters carefully.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Related Concept Videos
Biological Effects of Radiation
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Measures of Central Tendency
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...