Related Experiment Video
Updated: Feb 10, 2026

Implementation of a Reference Interferometer for Nanodetection
Published on: April 26, 2014
Effects of Analyzer Detection Method, Ethnicity, and Reference Individuals on Reference Interval of Immature Platelet
Background:
Immature platelet fraction (IPF) is a new biomarker for thrombopoiesis and inflammation. However, the reference interval (RI) is wildly discrepant among published reports. This study aimed to establish the RI of IPF for a population in Taiwan and evaluate the effects the detection method of the analyzer, ethnicity, and reference individuals have on the RI of IPF.
Methods:
The RI of absolute IPF (A-IPF) and IPF% were established with healthy subjects from the outpatient services of the Health Management Department of Taichung Veterans General Hospital between January 1, 2015 and March 1, 2016. These values were used along with published reports for meta-analysis.
Results:
A-IPF (109/L) and IPF% of Taiwanese were 6.9 - 7.6 and 3.1 - 3.4, respectively. Significant differences were found when performing paired comparisons of the RI of A-IPF and IPF% published in reports. For A-IPF, there was only one paired comparison with a significant difference (Z > 1.96) across 6 reports. Thus, the contribution of the factors examined on the RI of IPF cannot be determined. For IPF%, there were 8 paired comparisons with significant differences across 10 reports. The discrepancy rates of RI for IPF% were 41.2%, 50.0%, and 25.0% with the difference of reference individuals, the analyzer method, and ethnicity, respectively.
Conclusions:
The RIs of Taiwanese for A-IPF and IPF% were established. Furthermore, the analyzer detection method and the reference individuals contribute to the discrepancy of the RI for IPF% and should be considered cautiously when the value of IPF is interpreted.
More Related Videos
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Inertial Frames of Reference
Non-inertial Frames of Reference
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Critical Numbers and the Closed Interval Method
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.

