Comparison of first-line and second-line terlipressin versus sole norepinephrine in fulminant ovine septic shock
Related Experiment Video
Updated: Feb 10, 2026

Transvaginal Mesh Insertion in the Ovine Model
Published on: July 27, 2017
Tim G Kampmeier1, Philip H Arnemann2, Michael Hessler2
1Department of Anaesthesiology, Intensive Care and Pain Medicine, University Hospital of Muenster, Muenster, Germany. kampmeier@uni-muenster.de.
Abstract:
The Surviving Sepsis Guidelines suggest the use of vasopressin in case of catecholamine-refractory septic shock. Terlipressin (TP) as a V1-selective AVP analogue is a potential alternative, though data regarding the first-line administration in septic shock are scarce. The present study explored and compared the effects of first-line vs. second-line infusion of TP or sole norepinephrine regarding organ function, fluid and norepinephrine requirements and survival in fulminant ovine septic shock. Peritoneal sepsis was induced in 23 ewes after laparotomy and faecal withdrawal from the caecum. After onset of shock, causal and supportive sepsis therapy (antibiotics, peritoneal lavage, fluids and open-label norepinephrine) was performed in all animals. Concurrently, animals were randomized to receive 0.9% sodium chloride (control group) or TP (2 µg∙kg-1∙h-1, first-line group) after shock onset. In the second-line TP group, TP (2 µg∙kg-1∙h-1) was started once norepinephrine requirements exceeded 0.5 µg∙kg-1∙min-1. No significant differences were found between groups regarding survival, haemodynamics as well as fluid- and catecholamine-requirements. Kidney function and electron microscopic kidney injury were comparable between groups. In the present model of fulminant ovine septic shock, first-line TP infusion had no significant effect on fluid and norepinephrine requirements or organ dysfunction as compared to second-line TP infusion or placebo.
Related Concept Videos
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits

