Feasibility of single-incision laparoscopy for ruptured ectopic pregnancies with hemoperitoneum
Yetkin Karasu1, Burak Akselim1
1a Obstetrics and Gynecology , Ankara Training and Research Hospital , Ankara , Turkey.
Background:
The aim of this study was to compare single-incision laparoscopic surgery (SILS) and conventional laparoscopy in ectopic pregnancies accompanied by severe hemoperitoneum.
Material And Methods:
The main outcome measures were duration of surgery, intraoperative bleeding quantity, complications, post-operative pain scores, additional analgesic requirements, and length of hospital stay.
Results:
A total of 53 women, 28 in the conventional laparoscopy group and 25 in the SILS group, participated in the study. There were no differences in demographic characteristics between the two groups. There were no differences in terms of variables including gestational week, beta human chorionic gonadotropin (βhCG) levels, and operation time. No intraoperative complications were observed in either group. The groups exhibited no significant differences regarding additional analgesic requirements or postoperative pain scores. However, pain at the sixth postoperative hour was lower in the SILS group. This effect was not observed at 12 and 24 hours.
Conclusion:
SILS appears to be effective and safe for the treatment of ruptured ectopic pregnancies accompanied by hemoperitoneum.
Related Concept Videos
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Angular Momentum: Single Particle
Single-pass Transmembrane Proteins
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...