Related Experiment Video
Updated: Feb 10, 2026

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Carotid Flow as a Surrogate for Cardiac Output Measurement in Hemodynamically Stable Participants.
Marian Sidor1, Lalith Premachandra2, Bishoy Hanna3
1Division of Rheumatology and Connective Tissue Research, Department of Medicine, RWJ-Rutgers University, New Brunswick, NJ, USA.
Carotid blood flow, measured by ultrasound, correlates with cardiac output. Systolic carotid flow (SCF) and corrected flow time (CFT) show promise for monitoring patient fluid status.
Area of Science:
- Cardiovascular Physiology
- Medical Ultrasound
- Hemodynamics
Background:
- Common carotid artery (CCA) blood flow assessment offers insights into patient hemodynamic status.
- Ultrasound is a non-invasive tool for evaluating blood flow dynamics.
Purpose of the Study:
- To assess the correlation between cardiac output and CCA hemodynamic parameters: systolic carotid flow (SCF), corrected flow time (CFT), and total carotid flow (TCF).
- To investigate the utility of leg compression maneuvers in simulating volume depletion and evaluating hemodynamic responses.
Main Methods:
- A pilot study involving 20 healthy volunteers.
- Hemodynamic parameters were measured in the CCA and heart at rest and during leg compression/passive leg raise maneuvers.
- Nonparametric Spearman correlation analysis was performed.
Main Results:
- A significant direct correlation was found between cardiac output and SCF (r=0.67, P<0.001).
- A significant direct correlation was observed between cardiac output and CFT (r=0.57, P<0.001).
- Total carotid flow (TCF) showed a weaker, non-significant correlation with cardiac output (r=0.41, P<0.06).
Conclusions:
- Carotid blood flow variations, particularly SCF and CFT, directly reflect changes in cardiac output and preload.
- Carotid flow parameters show potential as non-invasive surrogates for cardiac output monitoring.
- Further research is warranted to validate these findings for guiding fluid management and predicting fluid responsiveness.
More Related Videos
10:55A Piglet Perinatal Asphyxia Model to Study Cardiac Injury and Hemodynamics after Cardiac Arrest, Resuscitation, and the Return of Spontaneous Circulation
Published on: January 13, 2023
09:05Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
Published on: January 30, 2015
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Regulation of Water Output