Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Influence of image-viewers and artifacts on implant length measurements in cone-beam computed tomography: an in vitro
Lydia Vazquez1, Murali Srinivasan2, Firas Khouja1
1Department of Orofacial Rehabilitation, Oral and Maxillofacial Radiology University Clinics of Dental Medicine, University of Geneva Geneva Switzerland.
Abstract:
This preclinical in vitro study compared the accuracy of implant lengths measured in two different image-viewers, and examined whether implant-induced artifacts affected the implant length measurements on CBCT images. A resin edentulous mandibular model, with multiple adjacent implants in the posterior segments, was acquired with a CBCT machine. In two different image-viewers, two observers independently measured the implant length. Vertical measurements on CBCT images were carried out twice at each session, and repeated one week later. The results demonstrated no significant differences between actual and measured implant lengths. The differences in the mean error for vertical measurements using the two different image-viewers (cross-sectional images: OsiriX viewer = -0.01 ± 0.03 mm, NewTom viewer = -0.05 ± 0.09 mm, p-value = 0.056; sagittal images: OsiriX viewer = -0.03 ± 0.04 mm; NewTom viewer = -0.04 ± 0.10 mm, p-value = 0.24) were not statistically significant. This in vitro investigation suggests that the accuracy of implant length measurements on CBCT images was not influenced by image-viewers or by the presence of implant-induced artifacts. The presence of multiple adjacent implants in the posterior segments of the mandible is not likely to impact the measurements made between the implant apex and vital structures on CBCT images.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...