Related Experiment Video
Updated: Feb 10, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Assessment of oral appliance for obstructive sleep apnea patients
Eri Makihara1, Toshihiro Kawano1, Ryuichiro Miyajima1
1Division of Occlusion & Maxillofacial Reconstruction, Department of Oral Function, School of Dentistry Kyushu Dental University Kitakyushu Japan.
Abstract:
Although oral appliances (OAs) have become widely used for the management of obstructive sleep apnea (OSA), side effects of OAs are generally related to poor utilization. The purpose of the present study was to evaluate relationship between utilization and treatment efficacy of a boil-and-bite appliance for OSA patients. A total of 135 patients with OSA who had used an OAs were mailed a questionnaire to determine whether they were currently using the OA. If so, they were asked about OA use, improvement of signs and subjective symptoms, and utilization. Otherwise, they were asked to indicate why and when they quit using the OA. Results of overnight polysomnography (PSG) before and after treatment were reviewed. Of the 48 responding patients, 33 patients were currently using the OA. The most common complication was excessive salivation (n = 11). All indices from PSG excluding arousal index were significantly improved after treatment (p < 0.05). Thirty patients showed improved signs and subjective symptoms. Eight out of 12 subjects (66.7%) were successfully treated, achieving an apnea-hypopnea index (AHI) < 10/h and >50% reduction in apnea-hypopnea index. Of the 15 patients no longer using the OA, the primary reason for quitting was "no treatment effect" (n = 5). No indices from PSG recording differed between before and after treatment in the not-using group. These results suggest that both subjective and objective signs and symptoms improved with use of the OA in the using group. However, no signs and subjective symptoms or indices of sleep quality differed between before and after treatment in the not-using group. Device improvements are needed to achieve better treatment efficacy, and thus improve compliance. The present study evaluated relationship between utilization and treatment efficacy of a boil -and bite appliance for OSA patients. Device improvements are needed to achieve better treatment efficacy, thus improve compliance.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Stages of Sleep
Before sleep begins, in wakefulness, the brain exhibits primarily beta waves, which are high in frequency and low in amplitude, indicating alertness...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Understanding Sleep
The circadian rhythm, a nearly 24-hour cycle, is deeply influenced by environmental light cues. Light exposure directly affects the hypothalamus, which in turn regulates...

