Related Experiment Video
Updated: Feb 10, 2026

Detection of Extravascular Trypanosoma Parasites by Fine Needle Aspiration
Published on: August 7, 2019
Evaluation of Thyroid Lesions by Fine-needle Aspiration Cytology According to Bethesda System and its
Shirish S Nandedkar1, Monal Dixit2, Kamal Malukani2
1Department of Pathology, R. D. Gardi Medical College, Ujjain, India.
Background:
The Bethesda system is a uniform reporting system for thyroid cytology that facilitates the clarity of communication among cytopathologists, radiologists, and surgeons and facilitates cytohistologic correlation for thyroid diseases.
Objective:
This study was carried out to evaluate thyroid lesions by fine-needle aspiration cytology (FNAC) based on Bethesda system of reporting and to correlate the cytological findings with histopathology.
Materials And Methods:
A total of 606 patients with thyroid lesions were studied by FNAC at our institute between January 1, 2006, and January 31, 2016, and results were compared with histopathology wherever possible.
Results:
Based on the Bethesda system of classification of thyroid lesions, out of 580 satisfactory samples; 501 lesions were diagnosed as benign (Group 1), five were in category of atypical follicular lesion of atypia undetermined significance (Group 2), 55 were diagnosed as suspicious for follicular neoplasm (Group 3), 7 as suspicious for malignancy (Group 4), and 12 cases were malignant (Group 5). 26 aspirates were nondiagnostic even after reaspiration. In the present study, cytohistopathological correlation was done in 148 benign and 18 malignant lesions. The sensitivity of FNAC was 85.7%, specificity 98.6%, and diagnostic accuracy 97.7%.
Conclusion:
Reviewing the thyroid FNAs with the Bethesda system for reporting allowed precise cytological diagnosis. It represents standardization and reproducibility in reporting thyroid cytology with improved clinical significance and greater predictive value. Nature of the disease, experience of cytopathologist, and understanding of certain limitations determine its diagnostic utility.
Related Concept Videos
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:
The Thyroid Gland
The follicles have a central cavity lined by simple cuboidal to squamous epithelial cells called follicular cells. These cells produce the glycoprotein...