Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
[Rhythm analysis of body surface potential mapping recordings from atrial fibrillation patients based on
Qingzhou Zhang1, Cuiwei Yang2, Baodan Bai3
1Department of Electronic Engineering, Fudan University, Shanghai 200433, P.R.China.
Abstract:
The study of atrial fibrillation (AF) has been known as a hot topic of clinical concern. Body surface potential mapping (BSPM), a noninvasive electrical mapping technology, has been widely used in the study of AF. This study adopted 10 AF patients' preoperative and postoperative BSPM data (each patient's data contained 128 channels), and applied the autocorrelation function method to obtain the activation interval of the BSPM signals. The activation interval results were compared with that of manual counting method and the applicability of the autocorrelation function method was verified. Furthermore, we compared the autocorrelation function method with the commonly used fast Fourier transform (FFT) method. It was found that the autocorrelation function method was more accurate. Finally, to find a simple rule to predict the recurrence of atrial fibrillation, the autocorrelation function method was used to analyze the preoperative BSPM signals of 10 patients with persistent AF. Consequently, we found that if the patient's proportion of channels with dominant frequency larger than 2.5 Hz in the anterior left region is greater than the other three regions (the anterior right region, the posterior left region, and the posterior right region), he or she might have a higher possibility of AF recurrence. This study verified the rationality of the autocorrelation function method for rhythm analysis and concluded a simple rule of AF recurrence prediction based on this method.
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...