[Optimization of end-tool parameters based on robot hand-eye calibration].
Lilong Zhang1, Tong Cao1, Da Liu2
1School of Mechanical Engineering, USTB, Beijing 100083, P.R.China.
Summary
A novel one-time registration method simplifies surgical robot hand-eye calibration. This approach optimizes end-tool parameters, enhancing positioning accuracy for clinical applications.
Area of Science:
- Robotics
- Surgical Technology
- Computer Vision
Context:
- Surgical robot hand-eye calibration is crucial for precision.
- Existing methods can be time-consuming and complex.
- Accurate calibration is essential for minimally invasive procedures.
Purpose:
- To develop a simplified one-time registration method for surgical robot hand-eye calibration.
- To introduce a practical method for optimizing surgical robot end-tool parameters.
- To enhance the efficiency and accuracy of surgical robot calibration.
Summary:
- A novel one-time registration method uses a fixed binocular camera to recognize an end-tool marker, calculating its position and orientation via robot joint parameters.
- This establishes the relationship between camera and robot base coordinate systems for calibration.
- An error equation, considering manufacturing and assembly inaccuracies, is used with numerical optimization to refine end-tool parameters.
Impact:
- The one-time registration method significantly improves calibration efficiency over existing techniques.
- Parameter optimization enhances the absolute positioning accuracy of the calibration method.
- The improved accuracy meets the stringent requirements for clinical surgical applications.
Related Concept Videos
Glassware Calibration
1.5K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.5K
Instrument Calibration
782
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
782
Hand hygiene
6.1K
Asepsis is the practice of preventing or breaking the chain of infection. The nurse employs aseptic techniques to prevent the spread of microorganisms and reduce the risk of diseases. Hand hygiene is the cornerstone of aseptic techniques and is classified into medical and surgical asepsis. Medical asepsis includes hand hygiene and the use of gloves. Surgical asepsis, or the sterile technique, refers to practices that render and keep objects and areas free of microorganisms.
Hand washing...
Hand washing...
6.1K
Calibration Curves: Correlation Coefficient
5.0K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
5.0K
Plotting and Calibrating the Root Locus
482
Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
482
Wave Parameters
9.4K
The simplest mechanical waves are associated with simple harmonic motion and repeat themselves for several cycles. These simple harmonic waves can be modeled using a combination of sine and cosine functions. Consider a simplified surface water wave that moves across the water's surface. Unlike complex ocean waves, in surface water waves, water moves vertically, oscillating up and down, whereas the disturbance of the wave moves horizontally through the medium. If a seagull is floating on the...
9.4K