AvalonElite Double Lumen Cannula for Total Cavopulmonary Assist in Failing Fontan Sheep Model with Valved
Cheng Zhou1,2, Dongfang Wang1, Francesca Condemi1
1From the Cardiothoracic Division, Department of Surgery, University of Kentucky, Lexington.
Abstract:
The AvalonElite double lumen cannula (DLC) provides total cavopulmonary assist (CPA) in failing Fontan sheep, but recirculation limits reliability. To improve CPA performance, a two-valve extracardiac conduit (ECC) was used to bracket infusion blood toward pulmonary artery (PA). A total cavopulmonary connection with failing Fontan circulation adult sheep model was created with valved ECC (n = 6). The valved ECC was connected to superior/inferior venae cavae (SVC/IVC) and right PA. The AvalonElite DLC was inserted from right jugular vein with infusion opening between the ECC valves. The DLC drainage lumen withdrew blood from SVC/IVC, and the infusion lumen returned blood to ECC. A failing Fontan sheep model with valved ECC was successfully created. Central venous pressure increased from 9 ± 1 to 17 ± 1 mm Hg, systolic arterial pressure decreased from 103 ± 9 to 51 ± 13 mm Hg, and cardiac output decreased from 3.6 ± 0.3 to 1.4 ± 0.2 L/min. Serum lactate significantly increased, indicating poor tissue perfusion. At 4 L/min pumping flow, the AvalonElite DLC returned hemodynamics/lactate to baseline levels throughout 6 hour CPA. Necropsy revealed intact/well-functioning ECC valves and well-positioned DLC with no visible thrombosis. The AvalonElite DLC provides reliable CPA performance in failing Fontan sheep with valved ECC.
Related Concept Videos
Cloning of Dolly the Sheep
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Fixing Double-strand Breaks
Fixing Double-strand Breaks