Insights
Focused cardiac ultrasound (FoCUS) implementation in a pediatric emergency department (PED) significantly increased FoCUS utilization and study quality. Physician-sonographer interpretation demonstrated high accuracy for key cardiac conditions.
Area of Science:
- Pediatric Emergency Medicine
- Cardiology
- Point-of-Care Ultrasound
Background:
- Focused cardiac ultrasound (FoCUS) is a valuable tool in emergency settings.
- Standardized protocols are crucial for effective implementation in pediatric emergency departments (PEDs).
- Evaluating the impact of a new FoCUS protocol is essential for quality improvement.
Purpose of the Study:
- To assess the implementation of a novel FoCUS protocol within a PED.
- To evaluate the diagnostic performance of physician-sonographers using the FoCUS protocol.
- To measure changes in FoCUS utilization and image quality post-protocol implementation.
Main Methods:
- A cross-sectional, observational quality improvement project was conducted.
- A FoCUS protocol was collaboratively developed by pediatric cardiology and emergency medicine specialists.
- Physician-sonographer performance was benchmarked against pediatric cardiologist interpretations of stored images.
Main Results:
- Ninety-two FoCUS examinations were performed by 34 physician-sonographers.
- High sensitivity and specificity were observed for detecting pericardial effusion, depressed left ventricular function, and chamber size abnormalities.
- Median monthly FoCUS use increased from 1 to 5, with adequate study rates rising from 0% to 55%.
Conclusions:
- The collaborative development and implementation of a PED FoCUS protocol were successful.
- Physician-sonographer interpretation of FoCUS provided acceptable diagnostic results.
- Significant improvements in FoCUS utilization and the quality of captured images were achieved.
Objectives:
The objective of this study was to evaluate the implementation of a focused cardiac ultrasound (FoCUS) protocol in a pediatric emergency department (PED).
Methods:
We conducted a cross-sectional, observational, quality improvement project in a PED of an urban tertiary care children's hospital. A FoCUS protocol was collaboratively developed by pediatric cardiology and pediatric emergency medicine. This included a reference document with definitions, indications, image acquisition guidelines, and interpretation expectations. We measured physician-sonographer performance against pediatric cardiologist interpretation of stored cine clips as our reference standard. Focused cardiac ultrasound interpretation was dichotomized for the presence or absence of pericardial effusion, depressed left ventricular function, and chamber size abnormalities. Run charts were used to compare the number FoCUS performed each month and the quality of captured cine clips with those from the previous year.
Results:
Ninety-two FoCUSs were performed by 34 different physician-sonographers from January to December 2016. The prevalence of FoCUS abnormalities was 18.5%. For pericardial effusion, sensitivity was 100% (95% confidence interval [CI], 48%-100%) and specificity was 99% (95% CI, 94%-100%). For depressed function, sensitivity was 100% (95% CI, 54%-100%) and specificity was 99% (95% CI, 94%-100%). For chamber size abnormalities, sensitivity was 100% (95% CI, 54%-100%) and specificity was 95% (95% CI, 89%-99%). The median number of monthly FoCUS increased from 1 (preprotocol) to 5 (postprotocol), and the median rate of adequate studies increased from 0% to 55%.
Conclusions:
We report the collaborative development and successful implementation of a PED FoCUS protocol. Physician-sonographer interpretation of FoCUS yielded acceptable results. Improvements in FoCUS utilization and cine clip adequacy were observed.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Related Concept Videos
Introduction Cardiac Emergencies
Emerging Adulthood
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Pharmacokinetics in Pediatric Patients: Drug Excretion
Coping Strategies: Problem Focused
For example, consider a student who struggles to understand their...
Focusing of Light in the Eye