Related Experiment Video
Updated: Feb 10, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Optimization by Monte Carlo method of photon fluence from the X-ray beam spectrum in a bimodal tomographic system
H Olaya Davila1, S A Martínez-Ovalle2, H F Castro Serrato3
1Universidad Pedagógica y Tecnológica de Colombia, Tunja, Colombia; Departamento de Física, Universidad Nacional de Colombia, Bogotá D.C, Colombia.
Abstract:
A bimodal tomographic system with a RTW MCBM 65B-50Mo X-ray tube and a XPAD3s semiconductor camera that contains 8 bars, each one with 67,200 hybrid pixels are modeled in GEANT4 simulation code. Several conical X-ray spectra were simulated, particularly a spectrum with a peak energy of 17.4 keV used in tomography on small animals. Three phantoms located in the tomographic center were added to the simulation to evaluate the image quality and its magnification based on the simulation of different photon fluences and the rotation effect of the tomographic system with an average angular velocity of 360o per minute. The images were recorded and analyzed in 2D through ROOT software toolkit in virtual XPAD3 detector. The quantitative method 20-80% of the maximum intensity of radiation was used for obtain the contouring of the phantoms, this method is used in radiotherapy and radiodiagnosis imaging. For this purpose, the images were taken to DICOM format in order to estimate the optical density of the contours and to evaluate the optimum and minimum photon fluence to be used in the tomographic system in order to reduce the absorbed doses in the individuals. This study allowed to determine the optimal fluence to validate it with realistic fluences used in the tomographic prototype ClearPET /XPAD-CT and to make an intercomparison with the absorbed doses measured with detectors located in the tomographic center.
Related Concept Videos
The Electromagnetic Spectrum
The Electromagnetic Spectrum
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Mass Spectrum