Related Experiment Video
Updated: Feb 10, 2026

How to Obtain Reliable Visual Event-related Potentials in Newborns
Published on: October 24, 2019
Reliability of the Measurement of Cuboid Height in Midfoot Charcot Neuroarthropathy
Shyam Sheth1, Brian S Derner2, Andrew J Meyr3
1Resident, Podiatric Surgical Residency Program, Temple University Hospital, Philadelphia, PA.
Abstract:
Cuboid height is a quantitative radiographic measurement of the relationship of the inferior cuboid to the plantar osseous plane of the lateral column of the foot and might be associated with poor clinical outcomes in patients with midfoot Charcot neuroarthropathy. We evaluated the reliability of the cuboid height measured by a group of foot and ankle surgeons on subjects with midfoot Charcot neuroarthropathy. Ten board-certified foot and ankle surgeons, 10 residents, and 10 medical students measured the cuboid height on 11 lateral weightbearing radiographic projections of subjects with midfoot Charcot neuroarthropathy. Cuboid height measurements were grouped categorically with calculation of an intraclass correlation coefficient (ICC). Ten unique images were used, with 1 repeated image to provide a measure of intrarater agreement. The overall measure of reliability of cuboid height measurement was an ICC of 0.997. Specifically, the ICC was 0.987 for surgeons, 0.992 for residents, and 0.989 for students. Participants were in agreement with the repeated measure in 24 (80.0%) of 30 cases. Specifically, each group (surgeons, residents, and students) were each in agreement for 8 (80.0%) of 10 repeated measurements. In conclusion, these results demonstrate excellent reliability for radiographic measurement of cuboid height on subjects with midfoot Charcot neuroarthropathy. To the best of our knowledge, this is the first investigation to provide a measure of reliability for this radiographic outcome, which is potentially related to clinical outcomes in the evaluation and treatment of this challenging patient cohort.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
10:18Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices
Published on: January 27, 2017
Related Concept Videos
Reliability and Validity
Distribution Reliability and Automation
Measurement: Standard Units
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measures of Central Tendency
Measuring Reaction Rates