Related Experiment Video
Updated: Feb 10, 2026

Prehospital Thrombolysis: A Manual from Berlin
Published on: November 26, 2013
Practice Trends of Fibrinogen Monitoring in Thrombolysis
Claire Kaufman1, Thomas Kinney2, Keith Quencer3
1Department of Radiology, University of Utah, Salt Lake City, UT 84132, USA. claire.kaufman@hsc.utah.edu.
Abstract:
There is a lack of evidence or societal guidelines regarding the utility of fibrinogen monitoring during thrombolysis. The purpose of our study was to investigate the current use of monitoring fibrinogen levels during thrombolysis. A voluntary, anonymous online survey was sent to all physician members of the Society of Interventional Radiology, consisting of 23 questions related to practitioner demographics, thrombolysis protocol, and fibrinogen monitoring. There were 455 physician responses; 82% of respondents monitored fibrinogen levels during thrombolysis, of which 97% decreased or stopped tissue plasminogen activator based on the level. Self-reported estimates of significant bleeding events during thrombolysis were 1.86% in those who monitored fibrinogen and 1.93% in those who did not. Only 34% of all respondents report, in their clinical experience, having found low fibrinogen level to be correlated with bleeding events. There was no significant difference in self-reported major bleeding rates between practitioners who monitor and those who do not monitor fibrinogen. This high variability of clinical use of fibrinogen monitoring during catheter-directed thrombolysis is secondary to the paucity of scientific studies demonstrating its utility; further scientific investigation is needed to define the true utility of fibrinogen monitoring.
Related Concept Videos
Current Trends in Nursing I
Current Trends in Nursing II
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...

