Robotics in Surgery: A Modular Robotic Platform Driven Gastric Wedge Resection
Published on: February 7, 2025
A robotic suture-passing device for possible use in SILS and NOTES.
Muhammad Umar Farooq1, Woo Young Kim1, Seong Young Ko1
1Medical Robotics and Intelligent Control Laboratory (MeRIC-Lab), Graduate School of Mechanical Engineering, Chonnam National University, Gwangju, South Korea.
A new device simplifies suturing in minimally invasive surgeries like natural orifice transluminal endoscopic (NOTES) and single incisional laparoscopic surgery (SILS). This innovation addresses challenges in these procedures, potentially improving surgical outcomes.
Area of Science:
- Minimally Invasive Surgery
- Surgical Instrumentation
Background:
- Natural orifice transluminal endoscopic (NOTES) and single incisional laparoscopic surgery (SILS) are increasingly important surgical techniques.
- Suturing and knot-tying are difficult in NOTES and SILS due to limited workspace and instrument constraints.
Purpose of the Study:
- To develop an automated device for simplifying suture passing in NOTES and SILS.
- To overcome the challenges of intracorporeal suturing in minimally invasive procedures.
Main Methods:
- An intracorporeal suture-passing device with two manipulator arms was designed.
- The device can deploy sutures around ducts up to 7 mm in diameter through a 3 mm inner diameter trocar.
Main Results:
- The device's mechanism was validated in 15 trials on a phantom tube.
- The average operating time for passing the suture was 34.55 ± 4.55 seconds.
Conclusions:
- The proposed device automates suture passing, addressing a key challenge in NOTES and SILS.
- Further clinical evaluation of prototypes is expected to confirm the device's efficacy.
More Related Videos
05:54Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
07:49Rod-based Fabrication of Customizable Soft Robotic Pneumatic Gripper Devices for Delicate Tissue Manipulation
Published on: August 2, 2016
Related Concept Videos
First Pass Effect
Depending on the route of administration, drugs can be metabolized in the liver, intestine, lungs, and vasculature. Orally administered drugs are first absorbed through the...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Single-pass Transmembrane Proteins
Factors Influencing Bioavailability: First-Pass Elimination
Insertion of Single-pass Transmembrane Proteins in the RER
Integral transmembrane proteins possess transmembrane and extra membrane domains. The transmembrane domains are primarily made of 20-25 hydrophobic amino acids arranged in a helical secondary confirmation. These...
Insertion of Multi-pass Transmembrane Proteins in the RER
The multipass transmembrane proteins are the type IV integral membrane proteins with multiple topogenic sequences determining their spatial arrangement in the ER membrane. Nearly all multipass proteins lack a cleavable signal sequence and use...