Risk of Collateral Lead Damage in Percutaneous Cardiac Implantable Electronic Device Extraction
Faris Khan1, Gustaf Sverin1, Ulrika Birgersdotter-Green1
1Section of Electrophysiology, Division of Cardiology, Department of Medicine, School of Medicine, University of California, San Diego, La Jolla, California.
Objectives:
This study sought to assess the risk of collateral lead damage during cardiac implantable electronic device extraction.
Background:
With the increasing numbers of cardiovascular implantable electronic devices, there has been an increase in the number of percutaneous device and lead extractions. It is unknown how often collateral damage (defined as the need for unintended lead extraction, or loss of lead's integrity or dislodgement) occurs in the planned retained leads.
Methods:
In this retrospective study, 108 patients who underwent incomplete cardiovascular implantable electronic device removal at the University of California, San Diego from September 2010 to September 2015 were included. The authors established the integrity of previously functioning leads at the end of each procedure as well as on follow-up visits using parameters including lead impedance change, threshold change, drop in P- or R-wave signal amplitude, or presence of lead noise.
Results:
Only 4 of 143 leads (2.7%) were found to have collateral damage. One right atrial (RA) lead had a clear insulation break, the second RA lead was found dislodged, and the third RA had a constant noise. The right ventricular lead was found to have a new high pacing threshold. Collateral lead age, extracted lead implantation site, collateral lead implantation site, and mode of lead extraction (laser, traction, or rotational dilator) did not have a significant correlation with the outcome of collateral lead damage.
Conclusions:
Lead extraction can be performed safely; however, there is a small risk of damaging adjacent leads. Close follow-up is needed, especially for the first few months, to assess for the reconnected leads' integrity.
More Related Videos
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Related Concept Videos
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Electron Affinity
Relative Risk
Sympathetic Pathways: Collateral Ganglia and Adrenal Medulla
Collateral Ganglia
Sympathetic preganglionic axons reach the collateral ganglia along the route of splanchnic nerves. These nerves bypass the sympathetic trunk and communicate with sympathetic postganglionic neurons housed in the prevertebral ganglia. These ganglia supply the organs of the abdominopelvic cavity.
The greater splanchnic nerve, formed by the...
Electron Transport Chains
The ETC is comprised of...
Electron Configuration of Multielectron Atoms