Read-out segmented echo planar diffusion imaging of the female pelvis-utility in endometrial carcinoma-a preliminary
Adarsh Ghosh1,2, Tulika Singh1, Veenu Singla1
11 Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research , Chandigarh , India.
Objective::
Susceptibility artefacts from bones and bowel, geometric distortion makes diffusion imaging of the pelvis difficult. We discuss the difficulties of single-shot-echo-planar (ss-ep) DWI and evaluate a new diffusion-weighted imaging (DWI) technique-readout segmented echo planar (rs-ep) DWI in endometrial carcinoma and discuss the imaging physics.
Methods::
Institute review board approval was obtained and five consecutive patients underwent both rs-ep and ss-ep-DWI of the female pelvis and two radiologists compared the images. ROIs were drawn on the endometrium on the b400 images-signal to noise was calculated and compared using F test.
Results::
The rs-ep-DWI had less imaging artefacts, less bowel-related susceptibility and geometric distortion compared to ss-ep-DWI. There was statistically significant greater SNR in ss-ep-DWI compared to rs-ep-DWI. This resulted in increased graininess of the readout segmented diffusion images. Artefacts in SS-EPI-DTI may make fibre tracking fallacious and rs-ep DTI may have fewer artefacts.
Conclusion::
rs-ep-DWI is a new imaging arsenal in imaging of the female pelvis in general; however further reduction in imaging time and improvement in signal to noise may be desirable.
Advances In Knowlegde::
rs-ep-DWI affords lesser imaging artefacts from susceptibility and geometric distortion; at a higher time dividend and may find a place in oncological imaging.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Diffusion
Diffusion
Uncertainty in Measurement: Reading Instruments
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Veins of the Abdomen and Pelvis
The inferior vena cava is fed by numerous smaller veins. The lumbar veins, for instance, drain the posterior abdominal wall, emptying both directly into the inferior vena cava and into the...