Ictal and interictal electric source imaging in pre-surgical evaluation: a prospective study
P Sharma1,2, M Scherg3, L H Pinborg4,5
1Department of Clinical Neurophysiology, Danish Epilepsy Centre, Dianalund, Denmark.
Electric source imaging (ESI) for localizing epileptic foci in drug-resistant epilepsy is feasible for both interictal (II) and ictal (IC) discharges. Accuracy of ESI is comparable to conventional neuroimaging, aiding surgical decisions.
Area of Science:
- Neuroscience
- Medical Imaging
- Epileptology
Background:
- Accurate epileptic focus localization is critical for drug-resistant epilepsy surgical treatment.
- Electric Source Imaging (ESI) is increasingly used in pre-surgical evaluation.
- Limited prospective studies compare interictal (II) and ictal (IC) ESI feasibility and accuracy.
Purpose of the Study:
- To prospectively compare the feasibility and accuracy of interictal (II) and ictal (IC) Electric Source Imaging (ESI).
- To evaluate ESI methods (ECD and DSM) against conventional neuroimaging and intracranial recordings.
- To assess ESI's correlation with surgical outcomes in drug-resistant epilepsy patients.
Main Methods:
- Prospective analysis of long-term video-electroencephalography (LTM) recordings in 87 epilepsy patients.
- Performed ESI using equivalent current dipole (ECD) and distributed source model (DSM) on II and IC signals.
- Compared ESI results with intracranial recordings, MRI, PET, SPECT, and 1-year post-operative seizure freedom.
Main Results:
- ESI localized focal abnormalities in 94% of patients, outperforming MRI (70%), PET (66%), and SPECT (64%).
- Agreement between ESI methods and intracranial recordings was moderate to substantial (k=0.56-0.79).
- Localization accuracy for II-ESI was 51-57%, and for IC-ESI was 51-62%, with no significant differences between ESI methods or compared to MRI.
Conclusions:
- Interictal (II) and ictal (IC) ESI of LTM data demonstrate high feasibility.
- ESI's localization accuracy is comparable to conventional neuroimaging methods (MRI, PET, SPECT).
- ESI is a valuable tool for pre-surgical evaluation in drug-resistant epilepsy.
More Related Videos
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016
06:45Generation and On-Demand Initiation of Acute Ictal Activity in Rodent and Human Tissue
Published on: January 19, 2019
Related Concept Videos
Sources and Properties of Electric Charge
Most atoms additionally constitute another fundamental particle, the neutron. It carries no electrical charge. A...
pre-mRNA Processing
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a “cap” to the 5’ end of the growing transcript. In this process, a 5’ phosphate is replaced by modified guanosine that has a methyl group attached to it (7-Methyl...
Pre-mRNA Processing: Modification of pre-mRNA Ends
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a cap to the 5' end of the growing transcript. In this process, a 5' phosphate is replaced by modified guanosine that has a methyl group attached (7-methyl guanosine). This 5' cap helps...
Imaging Studies VII: Vascular Imaging
Imaging Studies II: Ultrasonography
Imaging Studies I: Kidney, Ureter, and Bladder Studies